Product description
The CNG/LPG differential pressure sensor
has no output solution: confirm whether the differential pressure sensor is
reversed, the power polarity is connected correctly, measure the power supply
of the differential pressure sensor, whether it is 24V DC voltage; If there is no power supply, check whether
the loop is disconnected.If it is a
sensor with the table head, you can check whether the table head is damaged
(you can first short circuit the two wires of the table head, if the short
circuit is normal, it is the table head damage); If the watch head is damaged, replace the
watch head and connect the power meter to the 24V power supply loop to check
whether the current is normal. If the
current is normal, the CNG/LPG differential pressure sensor is normal. At this time, check whether other
instruments in the loop are normal and whether the power supply is connected to
the power input terminal of the pressure sensor. The pressure output pressure is too large
or too small solution: check whether the power supply of the CNG/LPG pressure
difference sensor is normal. If it is
too small, check whether there is a large load in the loop. Check whether the actual pressure used
exceeds the selected range of the differential pressure sensor, and select a
pressure sensor with an appropriate range. Check whether the connection is loose; Connect the cable and tighten it. if the power cable connection is correct, the power cable should be
connected to the corresponding terminal post.