Hybrid cable with copper and fiber optic
Your message must be between 20 to 2000 characters
Contact NowThe Hybrid cable is designed with copper power cable and fiber optic cable together , so it is one time for FTTA wiring , save a lot labor cost .
Application:
1. Adapted to Outdoor distribution.
2. Access network and local network in high electromagnetic interfering places.
3. Adapted to trunk power transmission system.
4. FTTA
Technical Parameters:
Construction of optical fiber cable.
Items |
Description |
|
Number of fiber |
4 G.657A |
|
Fiber optic Sub-cable, 2fiber each |
Sub-cable jacket |
PVC (Blue and Orange) |
PA tight buffer fiber |
0.87±0.05mm/clear PA ,blue and orange colored fiber |
|
Sub-cable diameter |
3.65±0.1mm |
|
10AWG copper stranded wire sub-cable |
Jacket |
THHW-PVC (red and black) |
Max. resistance 20℃ |
3.41Ω/km |
|
Diameter |
4.32±0.1mm |
|
Copper braid |
>90% |
|
Outer jacket |
PVC |
|
Color of Jacket |
Black ,UV resistant |
|
Out sheath thickness |
1.8±0.2mm |
|
FRP strength member diameter |
1.8mm |
|
Cable diameter |
12.8±0.2mm |
|
Approx. weight cable Kg/Km |
250 |
Mechanical and environmental data:
Temperature range |
Storage/Shipping temperature range Operating temperature range |
℃ |
-40℃ ~ +70℃ |
Min. Bending Radius |
Operation |
mm |
80mm |
Installation |
mm |
100mm |
|
Max. Tension (N) |
Short-term |
N |
1600 |
Long-term |
N |
500 |
|
Max. Crushing Resistance (N/100mm²) |
Short-term |
N/100mm |
1800 |
Long-term |
N/100mm |
500 |
Optical Preformances:
Optical Transmission Performance |
Single mode 1310/1550nm |
Multimode 850/1300nm |
|||
9/125μm (OS2) |
62.5/125μm (OM1) |
50/125 μm (OM2) |
50/125 μm (OM3) |
50/125 μm (OM4) |
|
Max. Attenuation(dB/km) |
0.4/0.3 |
3.5/1.5 |
3.5/1.5 |
3.5/1.5 |
3.5/1.5 |
Typ. Attenuation(dB/km) |
0.34/0.21 |
2.7/0.6 |
2.5/0.7 |
2.3/0.6 |
2.3/0.6 |
Bandwidth (MHz/km) |
N/A |
200/600 |
500/500 |
1500/500 |
3500/500 |
850nm laser bandwidth(MHz/km) |
N/A |
N/A |
N/A |
2000 |
4700 |
Numerical aperture |
0.13±0.01 |
0.275±0.015 |
0.200±0.015 |
0.200±0.015 |
0.200±0.015 |