1:16 PLC splitter with SC APC connector
Your message must be between 20 to 2000 characters
Contact NowThe 1:16 PLC splitter is with one input and 16 output ports which suitable for 16 endusers for one fiber in FTTH project . The laser signal is devided equally to 16 different channel with SC connector , so we must have excellent performance for optical splitters and SC connectors with low insertion loss and low PDL .
PLC ,Planar lightwave circuit splitter is a type of optical power management device that is fabricated using silica optical waveguide technology. It features small size, high reliability, wide operating wavelength range and good channel-to-channel uniformity, and is widely used in PON networks to realize optical signal power splitting. Fibercan provides whole series of 1xN and 2xN splitter products that are tailored for specific applications. All products meet GR-1209-CORE and GR-1221-CORE requirements.
Features
Low Insertion loss
Low PDL
Compact Design
Good channel-to-channel uniformity
Wide Operating Wavelength:
From 1260nm to 1650nm
Wide Operating Temperature:
From -40℃ to 85℃
High Reliability and Stability
Applications
FTTX Systems
PON Networks
CATV Links
Optical Signal Distribution
Compliance
Telcordia GR-1209-CORE
Telcordia GR-1221-CORE
RoHS
Specifications
Table 1 – 1×N PLC Splitter
Parameters |
1×2 |
1×4 |
1×8 |
1×16 |
1×32 |
1×64 |
Operating Wavelength (nm) |
1260~1650 |
|||||
Fiber Type |
G657A or customer specified |
|||||
Insertion Loss (dB)(P/S Grade) |
3.8/4.0 |
7.1/7.3 |
10.2/10.5 |
13.5/13.7 |
16.5/16.9 |
20.5/21.0 |
Loss Uniformity (dB) |
0.4 |
0.6 |
0.8 |
1.2 |
1.5 |
2.0 |
Return Loss (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
Polarization Dependent Loss(dB) |
0.2 |
0.2 |
0.2 |
0.25 |
0.3 |
0.35 |
Directivity (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss(dB) |
0.3 |
0.3 |
0.3 |
0.5 |
0.5 |
0.5 |
Temperature Stability(-40~85 ℃)(dB) |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
Operating Temperature (℃) |
-40~85 |
|||||
Storage Temperature (℃) |
-40~85 |
|||||
Device Dimension (mm) (L×W×H) |
40×4×4 |
40×4×4 |
40×4×4 |
50×4×4 |
50×7×4 |
60×12×4 |
Module Dimension (mm) (L×W×H) |
100×80×10 |
100×80×10 |
100×80×10 |
120×80×18 |
120×80×18 |
140×115×18 |
Mini-Module Dimension (mm) (L×W×H) |
50×7×4 |
50×7×4 |
60×7×4 |
60×12×4 |
80×20×6 |
N/A |
Table 2 – 2×N PLC Splitter
Parameters |
2×2 |
2×4 |
2×8 |
2×16 |
2×32 |
2×64 |
Operating Wavelength (nm) |
1260~1650 |
|||||
Fiber Type |
G657A or customer specified |
|||||
Insertion Loss (dB) |
4.0 |
7.6 |
11.0 |
14.4 |
17.5 |
21.0 |
Loss Uniformity (dB) |
0.6 |
1.0 |
1.2 |
1.5 |
1.8 |
2.2 |
Return Loss (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
Polarization Dependent Loss(dB) |
0.2 |
0.2 |
0.3 |
0.3 |
0.4 |
0.4 |
Directivity (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss(dB) |
0.3 |
0.4 |
0.5 |
0.5 |
0.5 |
0.5 |
Temperature Stability(-40~85 ℃)(dB) |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
Operating Temperature (℃) |
-40~85 |
|||||
Storage Temperature (℃) |
-40~85 |
|||||
Device Dimension (mm) (L×W×H) |
40×4×4 |
50×4×4 |
50×4×4 |
50×7×4 |
60×7×4 |
60×12×4 |
Module Dimension (mm) (L×W×H) |
100×80×10 |
100×80×10 |
100×80×10 |
120×80×18 |
140×115×18 |
140×115×18 |
Mini-Module Dimension (mm) (L×W×H) |
60×7×4 |
60×7×4 |
60×7×4 |
60×12×4 |
80×20×6 |
N/A |
Notes:
1. Specified without connectors.
2. Add an additional 0.15dB loss per connector.