Charger lithium Rechargeable Batteries Aa
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
LONG LIFE LFP6180L BATTERY
The LFP6180L BATTERY is desgined for general purpose and long life, focus on improving trickle life that base on FP series. Main features as follow:
When it is used in safe surroundings, the battery is maintenance free, no need adding water and it can be recharged repeatedly.
ü With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
ü With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
ü Long life, low self-discharge rate and high reliability.
ü It has safety, low resistance so recharge is easy and energy output is more remarkable.
ü Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
ü Standby use.
ü High rate discharge construction.
ü Deep discharge recoverability.Chargerlithium Rechargeable Batteries Aa
ü Batteries are strictly tested by our patented computer charge/discharge system.
ü ISO9001, 14001, OHSMS 18001 certified.
ü UL recognized components under UL 1989 (file number MH14533).
ü Complies with IATA/ICAO Special Provision A67 for air transport.
ü Classified per MG Amendment 27 as a non-hazardous material for water transport.
ü Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
International certifications:
- ISO9001 approval, FN: Q3105105131
- ISO14001 CTC04912E10302ROM
- OHS MS18001 04912S10150ROM
- UL approval, FN:MH28204
- CE approval, FN:G2M20201-0102-E-16
- KS approval, FN:KS C 8519
- VDS approval
- BS approval
General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- Front terminal,convenience for facilitate testing and servicing.
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
-
1.UPS and EPS
2.Emergency lightp
3.Railway signal and aircraft signal system
4.Marine and power stations
5.Alarm and security system;
6.Electronic apparatus and equipment
7.Communication power supply, DC power supply
Specifications
Nominal Voltage |
6 V |
||
Capacity (25℃) |
10HR(5.40V) |
180 Ah |
|
5HR(5.25V) |
157Ah |
||
1HR(4.80V) |
112Ah |
||
Dimension |
Length |
307±2mm (12.09inch) |
|
Width |
169±2mm (6.65inch) |
||
Height |
220±2mm (8.66inch) |
||
Total Height |
225±2mm (8.86inch) |
||
Approx. Weight |
27.5kg (60.6lbs)±4% |
||
Terminal type |
T11 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 2.2mΩ |
||
Capacity affected by temperature (10HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
6.75 to 6.90V Temperature compensation: -9mV/℃ |
||
Cyclic charging voltage(25℃) |
7.25 to 7.45V Temperature compensation: -15mV/℃ |
||
Maximum charging current |
54A |
||
Terminal material |
Copper |
||
Maximum discharge current |
1400A(5 sec.) |
||
Designed floating life(20℃) |
15years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
4.80V |
291 |
176 |
112 |
65.8 |
45.9 |
37.6 |
32.1 |
28.1 |
22.0 |
18.3 |
9.62 |
4.95V |
284 |
173 |
110 |
65.4 |
45.6 |
37.4 |
31.9 |
27.9 |
21.9 |
18.3 |
9.60 |
5.10V |
274 |
168 |
107 |
64.8 |
45.3 |
37.2 |
31.7 |
27.7 |
21.8 |
18.2 |
9.57 |
5.25V |
264 |
164 |
105 |
63.8 |
45.0 |
36.9 |
31.5 |
27.5 |
21.6 |
18.1 |
9.52 |
5.40V |
250 |
158 |
102 |
62.2 |
43.7 |
35.8 |
30.6 |
26.7 |
21.0 |
18.0 |
9.45 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME |
15min |
30min |
60min |
2h |
3h |
4h |
5h |
6h |
8h |
10h |
20h |
4.80V |
1598 |
990 |
636 |
381 |
270 |
221 |
190 |
166 |
131 |
109 |
57.7 |
4.95V |
1560 |
970 |
627 |
379 |
268 |
220 |
189 |
165 |
130 |
109 |
57.6 |
5.10V |
1502 |
940 |
611 |
375 |
266 |
218 |
187 |
164 |
129 |
109 |
57.4 |
5.25V |
1451 |
917 |
599 |
370 |
265 |
217 |
186 |
163 |
128 |
108 |
57.1 |
5.40V |
1374 |
884 |
580 |
360 |
257 |
210 |
181 |
158 |
124 |
107 |
56.7 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.