LFP12150HR is a typical high rate discharge battery special designed for all kinds of high-power-ouput using application,
It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing
Main features as follow:
* Standby use.
* High rate discharge construction.Rechargeable Batteries and Charger Aa
* ISO9001, 14001, OHSMS 18001 certified.* UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).
*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
* When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
* Batteries are strictly tested by computer charge/discharge system.
* Complies with IATA/ICAO Special Provision A67 for air transport.
* Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
Specifications
Nominal Voltage |
12 V |
||
Number of cell |
6 cells |
||
Capacity(10HR, 25℃) |
150 Ah |
||
Capacity(15min.rate, 25℃) |
535 Watts/cell |
||
Dimension |
Length |
485±2mm (19.09inch) |
|
Width |
172±2mm (6.77inch) |
||
Height |
240±2mm (9.45inch) |
||
Total Height |
T5: 242±2mm (9.53inch) |
||
T11: 240±2mm (9.45inch) |
|||
Approx. Weight |
47kg (103.6lbs)±5% |
||
Terminal type |
T5/T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 3.0mΩ |
||
Capacity affected by temperature (20HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
45A |
||
Terminal material |
Copper |
||
Maximum discharge current |
1200A(5 sec.) |
||
Designed floating life(20℃) |
7~10 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
4h |
5h |
10h |
20h |
1.60V/cell |
522 |
348 |
286 |
229 |
162 |
121 |
98.4 |
54.8 |
39.3 |
31.7 |
27.5 |
15.4 |
8.17 |
1.65V/cell |
506 |
337 |
279 |
223 |
159 |
118 |
96.9 |
54.5 |
39.1 |
31.5 |
27.4 |
15.4 |
8.15 |
1.67V/cell |
498 |
332 |
277 |
219 |
157 |
117 |
95.9 |
54.3 |
39.0 |
31.4 |
27.3 |
15.4 |
8.15 |
1.70V/cell |
485 |
323 |
269 |
215 |
154 |
115 |
94.5 |
54.0 |
38.8 |
31.3 |
27.2 |
15.3 |
8.13 |
1.75V/cell |
464 |
310 |
259 |
208 |
150 |
112 |
92.6 |
53.2 |
38.6 |
31.1 |
27.0 |
15.3 |
8.08 |
1.80V/cell |
438 |
292 |
246 |
197 |
145 |
108 |
89.7 |
51.8 |
37.4 |
30.1 |
26.2 |
15.2 |
8.03 |
Constant Power Discharge Characteristics (Watt/cell, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
4h |
5h |
10h |
20h |
1.60V/cell |
950 |
654 |
551 |
441 |
312 |
233 |
190 |
107 |
77.5 |
62.4 |
54.5 |
30.8 |
16.3 |
1.65V/cell |
921 |
644 |
538 |
430 |
306 |
228 |
187 |
106 |
77.0 |
62.0 |
54.2 |
30.8 |
16.3 |
1.67V/cell |
907 |
640 |
535 |
423 |
302 |
225 |
185 |
106 |
76.8 |
61.8 |
54.0 |
30.8 |
16.3 |
1.70V/cell |
883 |
628 |
518 |
415 |
297 |
221 |
182 |
105 |
76.5 |
61.6 |
53.8 |
30.7 |
16.3 |
1.75V/cell |
845 |
612 |
501 |
400 |
290 |
216 |
179 |
104 |
75.9 |
61.2 |
53.5 |
30.5 |
16.2 |
1.80V/cell |
798 |
599 |
474 |
379 |
279 |
208 |
173 |
101 |
73.7 |
59.3 |
51.9 |
30.3 |
16.1 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
Typical Applications:
Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System