Firstpower Tech. Co., Ltd.
Firstpower Tech. Co., Ltd.
Aaa Lithium Rechargeable Batteries and Charger
  • Aaa Lithium Rechargeable Batteries and Charger
Aaa Lithium Rechargeable Batteries and Charger

Aaa Lithium Rechargeable Batteries and Charger

Payment Type:
L/C, T/T, D/P
Incoterm:
FOB, CFR, CIF
Min. Order:
100 Piece/Pieces
Min. Order:
100 Piece/Pieces
Delivery Time:
30 Days
Transportation:
Ocean, Land
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: china
Productivity: 2000, 000kvah/ Year
Supply Ability: 2000, 000kvah/ Year
Payment Type: L/C,T/T,D/P
Incoterm: FOB,CFR,CIF
Certificate: iso,UL,CE
Transportation: Ocean,Land
Product Description
Product Description

 LFP1280AHR is a typical high rate discharge battery special designed for all kinds of high-power-ouput using application, 

It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing

Main features as follow:
*
 Standby use.  

*  High rate discharge construction.

* ISO9001, 14001, OHSMS 18001 certified.

  UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).

*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.

* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
*  Batteries are strictly tested by computer charge/discharge system.
*  Complies with IATA/ICAO Special Provision A67 for air transport.
*  Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.






Specifications

Nominal Voltage

12 V

Number of cell

6 cells

Capacity(10HR, 25)

80 Ah

Capacity(15min.rate, 25)

280 Watts/cell

Dimension

Length

260mm±2 (10.24inch)

Width

168mm±2 (6.61inch)

Height

211mm±2 (8.31inch)

Total Height

T5: 233±2mm (9.17inch)

T9: 214±2mm (8.43inch)

Approx. Weight

24.5kg (54.0lbs)±5%

Terminal type

T5/T9

Internal resistance

(Fully charged, 25)

Approx. 5mΩ

Capacity affected by temperature (20HR)

40

102%

25

100%

0

85%

-15

65%

Self-discharge

(25)

3 month

Remaining Capacity: 91%

6 month

Remaining Capacity: 82%

12 month

Remaining Capacity: 65%

Nominal operating temperature

25±3(77℉±5℉)

Operating temperature range

Discharge

-15~50(5℉~122)

Charge

-10~50(14℉~122)

Storage

-20~50(-4℉~122)

Float charging voltage(25)

13.50 to 13.80V

Temperature compensation:

-18mV/

Cyclic charging voltage(25)

14.50 to 14.90V

Temperature compensation:

-30mV/

Maximum charging current

24A

Terminal material

Copper

Maximum discharge current

800A(5 sec.)

Designed floating life(20)

7~10 years

◆ Absorbent glass mat technology;

◆ Recognized by UL & CE;

◆ ABS container.








 

Constant Current Discharge Characteristics (A, 25)

F.V/TIME

5min

10min

15min

20min

30min

45min

60min

2h

3h

5h

10h

20h

1.60V/cell

275

183

150

120

84.9

63.2

51.6

29.2

21.0

14.7

8.23

4.36

1.65V/cell

266

178

146

117

83.2

62.0

50.8

29.1

20.8

14.6

8.21

4.35

1.67V/cell

262

175

145

115

82.1

61.2

50.3

29.0

20.8

14.6

8.20

4.34

1.70V/cell

255

170

141

113

80.6

60.1

49.5

28.8

20.7

14.5

8.19

4.34

1.75V/cell

244

163

136

109

78.7

58.6

48.5

28.4

20.6

14.4

8.14

4.31

1.80V/cell

231

154

129

103

75.8

56.5

47.0

27.6

19.9

14.0

8.08

4.28

Constant Power Discharge Characteristics (Watt/cell, 25) 

F.V/TIME

5min

10min

15min

20min

30min

45min

60min

2h

3h

5h

10h

20h

1.60V/cell

500

364

289

231

164

122

99.6

57.0

41.3

29.1

16.5

8.71

1.65V/cell

485

354

282

226

161

120

98.1

56.7

41.1

28.9

16.4

8.70

1.67V/cell

477

349

280

222

159

118

97.1

56.5

40.9

28.8

16.4

8.69

1.70V/cell

465

340

272

217

156

116

95.6

56.2

40.8

28.7

16.4

8.67

1.75V/cell

445

326

262

210

152

113

93.7

55.3

40.5

28.5

16.3

8.62

1.80V/cell

420

309

249

199

146

109

90.8

53.9

39.3

27.7

16.2

8.56

Note: The above characteristics data can be obtained within three charge/discharge cycles. 





International certifications:
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval

BS approval


Typical Applications: 

Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System 




Send your message to this supplier

  • Ms. SALES