What's the Best Rechargeable Batteries
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
LFP1255HR is a typical high rate discharge battery special designed for all kinds of high-power-ouput using application,
It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing
Main features as follow:
* Standby use.
* High rate discharge construction.Rechargeable Batteries and Charger Aa
* ISO9001, 14001, OHSMS 18001 certified.* UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).
*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
* When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
* Batteries are strictly tested by computer charge/discharge system.
* Complies with IATA/ICAO Special Provision A67 for air transport.
* Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
Specifications
Nominal Voltage |
12 V |
||
Number of cell |
6 cells |
||
Capacity(10HR, 25℃) |
55 Ah |
||
Capacity(15min.rate, 25℃) |
190 Watts/cell |
||
Dimension |
Length |
229±2mm (9.02inch) |
|
Width |
138±2mm (5.43inch) |
||
Height |
208±2mm (8.19inch) |
||
Total Height |
T5: 230±2mm (9.06inch) |
||
T9: 211±2mm (8.31inch) |
|||
Approx. Weight |
18kg (39.7lbs)±5% |
||
Terminal type |
T5/T9 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 6mΩ |
||
Capacity affected by temperature (20HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
16.5A |
||
Terminal material |
Copper |
||
Maximum discharge current |
550A(5 sec.) |
||
Designed floating life(20℃) |
7~10 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
5h |
10h |
20h |
1.60V/cell |
190 |
126 |
102 |
81.6 |
57.8 |
43.1 |
35.1 |
20.1 |
14.4 |
10.1 |
5.65 |
3.00 |
1.65V/cell |
184 |
123 |
100 |
79.6 |
56.6 |
42.2 |
34.6 |
20.0 |
14.3 |
10.0 |
5.64 |
2.99 |
1.67V/cell |
181 |
121 |
99 |
78.3 |
55.9 |
41.7 |
34.2 |
19.9 |
14.3 |
10.0 |
5.64 |
2.99 |
1.70V/cell |
176 |
118 |
95.9 |
76.7 |
54.9 |
40.9 |
33.7 |
19.8 |
14.2 |
10.0 |
5.63 |
2.98 |
1.75V/cell |
169 |
113 |
92.6 |
74.1 |
53.6 |
39.9 |
33.1 |
19.5 |
14.1 |
9.90 |
5.59 |
2.96 |
1.80V/cell |
159 |
106 |
87.7 |
70.2 |
51.6 |
38.4 |
32.0 |
19.0 |
13.7 |
9.60 |
5.56 |
2.94 |
Constant Power Discharge Characteristics (Watt/cell, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
5h |
10h |
20h |
1.60V/cell |
330 |
228 |
197 |
157 |
112 |
83.1 |
67.8 |
39.2 |
28.4 |
20.0 |
11.3 |
5.99 |
1.65V/cell |
325 |
221 |
192 |
154 |
109 |
81.4 |
66.8 |
39.0 |
28.2 |
19.9 |
11.3 |
5.98 |
1.67V/cell |
317 |
217 |
191 |
151 |
108 |
80.4 |
66.1 |
38.8 |
28.2 |
19.8 |
11.3 |
5.97 |
1.70V/cell |
301 |
211 |
185 |
148 |
106 |
78.9 |
65.1 |
38.6 |
28.0 |
19.7 |
11.3 |
5.96 |
1.75V/cell |
297 |
202 |
179 |
143 |
103 |
77.0 |
63.8 |
38.0 |
27.8 |
19.6 |
11.2 |
5.93 |
1.80V/cell |
280 |
194 |
169 |
135 |
100 |
74.2 |
61.8 |
37.1 |
27.0 |
19.0 |
11.1 |
5.89 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
Typical Applications:
Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System
Related Keywords