FP12120HR is a typical high rate discharge battery special designed for all kinds of high-power-ouput using application,
It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing
Main features as follow:
* Standby use. D Cell Rechargeable Batteries and Charger
* High rate discharge construction.
* ISO9001, 14001, OHSMS 18001 certified.* UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).
*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
* When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
* Batteries are strictly tested by computer charge/discharge system.
* Complies with IATA/ICAO Special Provision A67 for air transport.
* Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
Specifications
Nominal Voltage |
12 V |
||
Number of cell |
6 cells |
||
Capacity(20HR, 25℃) |
12 Ah |
||
Capacity(15min.rate, 25℃) |
55 Watts/cell |
||
Dimension |
Length |
151±1.5mm (5.94inch) |
|
Width |
98±1mm (3.86inch) |
||
Height |
95±1mm (3.74inch) |
||
Total Height |
101±1mm (3.98inch) |
||
Approx. Weight |
4.0kg (8.82lbs)±5% |
||
Terminal type |
T2/T1 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 11mΩ |
||
Capacity affected by temperature (20HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.60 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
3.6A |
||
Terminal material |
Copper |
||
Maximum discharge current |
180A(5 sec.) |
||
Designed floating life(20℃) |
3~5 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
;mso-para-margin-left:-0.5000gd;line-height:12.0000pt;mso-line-height-rule:exactly;" >◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
5h |
10h |
20h |
1.60V/cell |
55.9 |
34.3 |
27.0 |
21.4 |
14.8 |
10.6 |
8.39 |
4.38 |
3.12 |
2.14 |
1.16 |
0.62 |
1.65V/cell |
54.2 |
33.2 |
26.3 |
20.9 |
14.5 |
10.4 |
8.26 |
4.36 |
3.10 |
2.13 |
1.15 |
0.62 |
1.67V/cell |
53.4 |
32.7 |
25.9 |
20.5 |
14.3 |
10.3 |
8.18 |
4.35 |
3.09 |
2.12 |
1.15 |
0.62 |
1.70V/cell |
52.0 |
31.9 |
25.4 |
20.1 |
14.1 |
10.1 |
8.05 |
4.32 |
3.08 |
2.11 |
1.15 |
0.62 |
1.75V/cell |
49.8 |
30.5 |
24.5 |
19.4 |
13.7 |
9.8 |
7.89 |
4.26 |
3.06 |
2.10 |
1.14 |
0.61 |
1.80V/cell |
47.0 |
28.8 |
23.2 |
18.4 |
13.2 |
9.5 |
7.65 |
4.15 |
2.97 |
2.04 |
1.12 |
0.60 |
Constant Power Discharge Characteristics (Watt/cell, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
5h |
10h |
20h |
1.60V/cell |
108 |
69.1 |
57.2 |
42.1 |
29.2 |
20.9 |
16.5 |
8.68 |
6.24 |
4.28 |
2.31 |
1.24 |
1.65V/cell |
105 |
67.1 |
56.1 |
41.1 |
28.6 |
20.5 |
16.3 |
8.63 |
6.21 |
4.26 |
2.31 |
1.24 |
1.67V/cell |
103 |
66.1 |
55.0 |
40.5 |
28.3 |
20.3 |
16.1 |
8.60 |
6.19 |
4.25 |
2.30 |
1.24 |
1.70V/cell |
99.4 |
64.5 |
53.0 |
39.6 |
27.7 |
19.9 |
15.9 |
8.55 |
6.16 |
4.23 |
2.29 |
1.23 |
1.75V/cell |
95.6 |
61.8 |
51.3 |
38.3 |
27.1 |
19.4 |
15.5 |
8.43 |
6.12 |
4.20 |
2.28 |
1.22 |
1.80V/cell |
91.2 |
58.5 |
49.7 |
36.2 |
26.1 |
18.7 |
15.1 |
8.21 |
5.94 |
4.07 |
2.23 |
1.20 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
Typical Applications:
Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System
Related Keywords