Shen,zhen.meian.technology Co., Ltd.
Shen,zhen.meian.technology Co., Ltd.
home alarm system wired and wireless glass break sensor with sound alarm
  • home alarm system wired and wireless glass break sensor with sound alarm
home alarm system wired and wireless glass break sensor with sound alarm

home alarm system wired and wireless glass break sensor with sound alarm

Delivery Time:
5 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Guangdong, China (Mainland)
Product Description
Product Description
Specifications Wireless glass break detector/ home alarm system/ sound and light alarm on spot.

Wireless Or Wired Glass Break Sensor       FG-2036R Wireless glass break detectors can detect breaking sound of ordinary glass, tamper glass, laminated glass, foil glass and double insulated glass. it is only for indoor use.     Porduct Specification

Detection distance

As far as 4.6 m(15ft), no minimum distance all-round

Adjustable sensitivity

high, medium, low, minimum

Supply voltage

Supply voltage

RF emitting frequency

433MHz

Wireless communication distance

100m(in open air)

Operating Temperature

:-20°C to 50°C

Product Size

115mm*72mm&27mm

    Table of nominal thickness of the glass

 

Nominal thickness

Minimum

Maximum

Ordinary glass

2mm(3/32in)

10mm(3/8in)

Tamper Glass

3mm(1/8in)

10mm(3/8in)

Laminated glass

3mm(1/8in)

14mm(9/16in)

Wired glass

6mm(1/4in)

6mm(1/4in)

foil glass

3mm(1/8in)

6mm(1/4in)

double insulated glass

3mm(1/8in)

[13mm(1/2in.)overall]

6mm(1/4in)

[19mm(3/4in.)overall]

Ordinary glass

7-8mm

400*400

    Product Photo              Product Installation The best installation location for FG-2036R is a wall or ceiling,the microphone should be directed to the protected glass surface.   To enable the detector to work best, we select the following installation location: *The detector should be no more than 4.6 m from the protected glass surface . *Detectors have a clear sight to the glass *The detector should be at least two meters from the door *The detector should be from the passive ventilation pipes at least one meter *The detector should be at least one meter from alarm siren and bell diameter of more than 5 cm    Sometimes there is cover material between the protected glass and thick glass .When there is cover material on thick glass , the detector can be mounted to the glass frame. To avoid installing detectors in a protected glass surface wall, we can’t install in the absence of fixed pillars and beams. Avoid indoor noise sources (air compressors, bells, electric tools, etc.),the work of these noise sources may cause the detector alarm.   Note: If you install the detector on the ceiling, the hole (microphone side) should face the protected glass.

Send your message to this supplier

  • Ms. Coin Zhou

  • Enter between 20 to 4,000 characters.