12V 24V 350W AC DC Switching Power Supply , Universal AC DC Power Adapter SMPS IEC60601
Your message must be between 20 to 2000 characters
Contact NowModel No:: | TFP350-12XX | Shell Material: | AL |
Warranty: | > 2 Years | Output Power: | 30 - 400w |
Input Voltage: | 110 - 220V | Connection Mode: | Series Swithching Power Supply |
Energy Transmission: | One - Way Transmission |
12V 24V 350W AC DC Switching Power Supply , Universal AC DC Power Adapter SMPS IEC60601
Medical Power Supply:
Universal AC input: 110/220± 20%
Fixed switching frequency at 47-63Hz
Protections: Short circuit/Overload/Over voltage
Output Type:Single |
Warranty:>2 Years
|
Output Power:301 - 400W |
Input Voltage:110-220V
|
Connection Mode:Series Switching Power Supply |
Starting Mode:Self-excited Switching Power Supply
|
Voltage Regulating Mode:Frequency Modulation Type |
Power Supplying System:Terminal Power Distribution Equipment
|
Energy Transmission:One-way Transmission |
Color:Silver
|
Shell Material:Aluminum |
Export Markets:Global |
Features:
● 100 ~ 240VAC universal AC input
● Protections:short circuit,overload
● Cooling by free air convection
● 100%Full load burn-in test
Size:100*100*42mm ●two years warranty
● Small volume,light weight,high efficiency
output |
DC output voltage |
12V |
24V |
|
Output voltage tolerance |
±1% |
±1% |
||
Rated output current |
10A |
5A |
||
Output current range |
0~5A |
0~5A |
||
Output power |
120W |
120W |
||
Ripple and noise |
100mVp-p |
180mVp-p |
||
DC adjustment range |
±5% |
±5% |
||
Setup,rise,hold time |
200ms,100ms,30ms/230VAC. |
|||
input |
AC input voltage range |
100~240VAC 47~63Hz |
||
AC input current(max) |
max0.84A |
|||
efficiency |
≥80% |
≥85% |
||
AC inrush current(max) |
Cold start 40A/230V |
|||
Leakage current(max) |
<3.5mA/240VAC |
|||
Protection characteristic |
Overload protection |
115%~135%rated output power ,start loading protection |
||
Protection mode:hiccup mode, Auto-recovery |
||||
Overvoltage protection |
115%~135%Shut down O/P , Auto-recovery |
|||
Over temp protection |
≥105℃Shut down O/P , Auto-recovery |
|||
environment |
Working temperature humidity |
-10℃~+60℃;20%~90%RH |
||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG :0.5KVAC |
||
Insulation resistance |
I/P-O/P : I/P-FG , O/P-FG :100M Ohms/500VDC |
|||
else |
Weight/packing |
0.498kg/40PCS/20kg/22kg BOX:50*43*23cm |
||
Remarks :1, When not especial specified, all the parameters are obtained under the conditions of input voltage is 230vac, nominal rated load and 25℃. 2, Ripple and noise voltage is obtained that in the 20MHz bandwidth oscilloscope's 12-inch twisted-pair terminal add capacitance 0.1u and 47u capacitance. 3, Tolerance is the sum total of the voltage setting error, voltage regulation factor and current adjust rate
|
DC output | 12V 29A | |||
Wave and noise | 75mVp-p | |||
Inlet stability | ±0.5% | |||
Load stability | ±0.5% | |||
Efficiency | 74% | |||
Adjustable range for DC voltage |
±10% |