Shenzhen Proyu Technology Co., Limited
Shenzhen Proyu Technology Co., Limited
Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
  • Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
  • Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
  • Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
  • Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
  • Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
  • Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200
Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200

Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200

Delivery Time:
3 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Guangdong, China (Mainland)
Product Description
Product Description
  Australia Standard Addressable Fire Alarm System Control Panel connect with smoke detector CFT-MN/300/200   Technical Specification: System capacity: 200 points (non-polarity, two buses, fully mixed coding) AC input voltage: AC 220V±20% 50Hz AC input power: 120W DC power: DC24V 5.0Ah, two fully sealed maintenance-free DC12V 5.0Ah storage batteries connected in series The 24V DC power has a long-term constant output current of 6A. The 5V DC power has a long-term constant output current of 4A. Circuit bus: two-wire system; total length: ≤1500m Voltage UL of the circuit bus: +20V≤UL≤+26V(when the DC power is operating) +24V≤UL≤+26V(when the AC power is operating) System working conditions 1.Temperature: -10°C~+50°C 2.Humidity: ≤95% 3.Power supply: AC 220V 50HZ          DC 24V 6A 4.Output contact capacity: AC 220V 1A   DC 27.6V 3A  
    Other Conventional Fire Alarm System:  
     

Send your message to this supplier

  • Ms. Sunny Xiong

  • Enter between 20 to 4,000 characters.