Shenzhen Week Technology Ltd.
Shenzhen Week Technology Ltd.
CE Approval CO2 Transmitter Carbon Dioxide Alarm
  • CE Approval CO2 Transmitter Carbon Dioxide Alarm
  • CE Approval CO2 Transmitter Carbon Dioxide Alarm
CE Approval CO2 Transmitter Carbon Dioxide Alarm
CE Approval CO2 Transmitter Carbon Dioxide Alarm

CE Approval CO2 Transmitter Carbon Dioxide Alarm

Delivery Time:
7 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China (Mainland)
Product Description
Product Description
CE Approval CO2 Transmitter Carbon Dioxide Alarm Model Number: F2000TSM-CO2-S100-V/A-05 Features
Real-time detecting CO2 level.
NDIR infrared CO2 module inside with four CO2 detection range selectable.
CO2 sensor has Self-Calibration Algorithm and 15 years lifetime
Wall-mounting
Providing one analog output with voltage or current selectable
0~10VDC/4~20mA selectable easily via jumpers
Special “L” series with 6 lights indicates CO2 level and makes CO2 level show clearly. Provide a special model with a on/off relay output with a touch button to operate a fan control. Design for HVAC, ventilation systems, offices, or other public places.
Modbus RS485 communication interface optional: 15KV antistatic protection, independent address setting
CE-Approval
For duct probe CO2 transmitter, and CO2+ Temp.+ RH 3 in 1 transmitter, please see our other products.
Specifications
Gas detected
Carbon Dioxide (CO2)
Sensing element
Non-Dispersive Infrared Detector (NDIR)
Accuracy@25(77),2000ppm ±40ppm + 3% of reading or ±75ppm (whichever is greater)
Stability
<2% of FS over life of sensor (15 yr typical)
Calibration interval
ABC Logic Self Calibration System
Response time
<2 minutes for 90% step change
Warm up time
2 hours (first time)
2 minutes (operation
CO2 measuring range
0~2,000ppm / 0~5,000ppm selectable in orders
0~20,000ppm / 0~50,000ppm just for TSM-CO2-S series
Sensor life
Up to 15 years
Power supply
24VAC/24VDC
Consumption
1.5 W max. ; 0.8 W avg.
Analog outputs
0~10VAC or 4~20mA selectable by jumpers
Relay output
1X2A switch load
Four set points selectable by jumpers
6 LED lights
(just for TSM-CO2-L series)
From left to right:
Green/Green/Yellow/Yellow/Red/Red
1st green light on as CO2 measurement600ppm
1st and 2nd green lights on as CO2 measurement>600ppm and800ppm
1st yellow light on as CO2 measurement>800ppm and1,200ppm
1st and 2nd yellow lights on as CO2 measurement>1,200ppm and1,400ppm
1st red light on as CO2 measurement>1,400ppm and1,600ppm
1st and 2nd red lights on as CO2 measurement>1,600ppm
Modbus interface
Modbus RS485 interface
9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV
antistatic protection.

Operation conditions
0~50(32~122); 0~95%RH, non condensing
Storage conditions
0~50(32~122)
Net weight
180g
Dimensions
100mm×80mm×28mm
Installation standard
65mm×65mm or 2”×4”wire box
Approval
CE-Approval
Models Guide
Type
Model
Description
CO2 Detector
(1xanalog,1Xon/off output)
F2000TSM-CO2-S100-V/A-02
1Xanalog output, CO2 range: 0~2,000ppm
F2000TSM-CO2-S100-V/A-05
1Xanalog output, CO2 range: 0~5,000ppm
F2000TSM-CO2-S100-V/A-20
1Xanalog output, CO2 range: 0~20,000ppm
F2000TSM-CO2-S100-V/A-50
1Xanalog output, CO2 range: 0~50,000ppm
F2000TSM-CO2-S110-V-02
1X0~10V output and 1xon/off output
CO2 range: 0~2000ppm
CO2 Detector
(1xanalog output, Modbus
RS485 interface)

F2000TSM-CO2-S101-V/A-02
1Xanalog output, Modbus RS485 communication.
F2000TSM-CO2-S101-V/A-05
1Xanalog output, Modbus RS485 communication
F2000TSM-CO2-S101-V/A-20
1Xanalog output, Modbus RS485 communication.
F2000TSM-CO2-S101-V/A-50
1Xanalog output, Modbus RS485 communication.
CO2 Detector
with 6 indicator lights
F2000TSM-CO2-L101-N-02/05
6 lights indicate CO2 measurements range,
Modbus interface
F2000TSM-CO2-L100V/A-02/05                              6 lights indicate CO2 measurements range,
1x analog output
F2000TSM-CO2-L101V/A-02/05             F2000TSM-CO2-L110-V-02
6 lights indicate CO2 measurements range,
1x analog output, Modbus RS485 interface                                                                     CO2 transmitter and indication, 1x 0~10VDC output, 1X
on/off output with a touch button. CO2 range: 0~2000ppm

F2000TSM-CO2-L110-N-02                      F2000TSM-CO2-L111-N-02

6 lights indicate CO2 measurements range,
1x relay output                                                                              6 lights indicate CO2 measurements range,
1x relay output, Modbus interface

Accessories
Power adaptor-E
Plug-in power adapter, Input: 100~240VAC ;
Output: DC 24V/ 240mA. European plug
Power adaptor- A
Plug-in power adapter, Input: 100~240VAC;
Output: DC 24V 240mA. American plug
Wiring Diagram Mounting

Send your message to this supplier

  • Ms. Yan

  • Enter between 20 to 4,000 characters.