CE Approval Carbon Dioxide Detector CO2 Monitor for Fan Switch Model Number:F2000TSM-CO2-8013
Features
Real-time detecting CO2 level with wall-mounting type
NDIR infrared CO2 module inside with four CO2 detection range selectable.   CO2 sensor has Self-Calibration Algorithm and up to 15 years lifetime
Six indicator lights indicate six CO2 range
An SPDT relay output with max. 8A to control a 3-wire fan. Two CO2 setpoints selectable for the relay switch by a jumper
 A touch button for operation
 Design for control a ventilator in houses, offices, or other indoor areas
 Wide power range:100~240VAC power supply
 CE-Approval   Specifications
Power supply
100~240VAC
Consumption
1.8 W Max / 230VAC
CO2 sensor Non-Dispersive Infrared Detector (NDIR)
ABC Logic Self Calibration
CO2 measuring range
0~2,000ppm
Accuracy@25(77), 2000ppm ±40ppm +3% reading
Stability
<2% of FS over life of sensor
Response time
<2 minutes for 90% step change
Warm up time for turning-on
48 hours (first time), 2 minutes (operation)

6 LED lights
From left to right:
Blue Blue Green Orange Red Red

 


 

1st blue light on as CO2 measurement600ppm
1st and 2nd blue lights on when 600ppm<CO2 measurement<800ppm
Green light on when 800ppm<CO2 measurement<1,000ppm
Orange light on when 1,000ppm<CO2 measurement<1,500ppm
1st red light on when 1,500ppm<CO2 measurement<2,000ppm
1st and 2nd red lights on as CO2 measurement>2,000ppm

 

Relay control
Max. switch current: 8A (load resistance) SPDT relay
Two CO2 levels selectable to control the relay by jumpers
Two CO2 level selectable
1000ppm/1500ppm
The differential is 300ppm
The shortest protection time for fan turning on/off
10 minutes
Operation conditions
0~50(32~122); 0~95%RH, non condensing
Storage conditions
0~50(32~122) 0~80%RH, non condensing
Dimensions/Net weight
100mm×80mm×24mm (H X W X D) /180g
Installment standard
65mm×65mm (2×4) wire box
Approval
CE

Wiring Diagram Mounting