OXY- Flex Oxygen Analyser High accuracy linear output
- Delivery Time:
- 7 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | United Kingdom |
---|
Product Description
Product Description
OXY- Flex Oxygen Analyser High accuracy linear output FEATURES:
• High accuracy linear output
• Configurable outputs: 4-20mA and 0-10VDC or RS232 comms interface • Selectable output measurement ranges: Standard ranges of 0-25% O2 and 0-100% O2 or fully adjustable via RS232 when configured in 0-100% O2 mode
• Externally triggered automatic or manual calibration • Can be calibrated in normal air (20.7% O2) or in any other known O2 concentration
• monitoring of the O2 sensor pump cycle for diagnostic purposes
• Selectable output filtering allows adaptive, fast and dynamic or slow and stable output SPECIFICATIONS:
Maximum ratings
Supply voltage : 24VDC ± 10%
Current consumption : 500mA max @ 24VDC
4-20mA: Load 100 to 600Ω
Temperature limits (electronics enclosure) Storage : -10 to 85'C
Operating : -10 to 85'C
Temperature limits (permissible gas temperature at sensor tip) Operating (Standard Temp) : -100 to 250'C
(High Temp) : -100 to 400'C
Gas flow rate : 0 to 10 m/s
Weight : <450g
Incidental permissible acceleration : 30g
Repetitive permissible acceleration : 5g
Sealing Rating : IP65 APPLICATIONS:
• Combustion control including oil, gas and biomass boiler applications
• Composting • Laboratory & building air quality monitoring including confined space personnel safety
• Industrial process control i.e. gas mixing for welding and steel making
• Oxygen generation systems
• Medical • Scientific including respiratory studies of acommunity or an organism, plants and animals
• Food and beverage packaging
• Applications where low oxygen is key including fermentation, rust and corrosion prevention, inerting and purging OXY-Flex Oxygen Analyser

Welcome to your inquiry
!
• High accuracy linear output
• Configurable outputs: 4-20mA and 0-10VDC or RS232 comms interface • Selectable output measurement ranges: Standard ranges of 0-25% O2 and 0-100% O2 or fully adjustable via RS232 when configured in 0-100% O2 mode
• Externally triggered automatic or manual calibration • Can be calibrated in normal air (20.7% O2) or in any other known O2 concentration
• monitoring of the O2 sensor pump cycle for diagnostic purposes
• Selectable output filtering allows adaptive, fast and dynamic or slow and stable output SPECIFICATIONS:
Maximum ratings
Supply voltage : 24VDC ± 10%
Current consumption : 500mA max @ 24VDC
4-20mA: Load 100 to 600Ω
Temperature limits (electronics enclosure) Storage : -10 to 85'C
Operating : -10 to 85'C
Temperature limits (permissible gas temperature at sensor tip) Operating (Standard Temp) : -100 to 250'C
(High Temp) : -100 to 400'C
Gas flow rate : 0 to 10 m/s
Weight : <450g
Incidental permissible acceleration : 30g
Repetitive permissible acceleration : 5g
Sealing Rating : IP65 APPLICATIONS:
• Combustion control including oil, gas and biomass boiler applications
• Composting • Laboratory & building air quality monitoring including confined space personnel safety
• Industrial process control i.e. gas mixing for welding and steel making
• Oxygen generation systems
• Medical • Scientific including respiratory studies of acommunity or an organism, plants and animals
• Food and beverage packaging
• Applications where low oxygen is key including fermentation, rust and corrosion prevention, inerting and purging OXY-Flex Oxygen Analyser