Shenzhen Week Technology Ltd.
Shenzhen Week Technology Ltd.
Thermal Flow Sensor for Flow Speed and Flow Direction Detection 0~50 m/s AFE-01
  • Thermal Flow Sensor for Flow Speed and Flow Direction Detection 0~50 m/s AFE-01
Thermal Flow Sensor for Flow Speed and Flow Direction Detection 0~50 m/s AFE-01

Thermal Flow Sensor for Flow Speed and Flow Direction Detection 0~50 m/s AFE-01

Delivery Time:
7 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: United Kingdom
Product Description
Product Description
           Thermal Flow Sensor for Flow Speed and Flow Direction Detection 0~50 m/s                                                                              Model Number: AFE-01                                                           Product
The AFE-01 consists of four platinum thin film resistors. The low ohmic resistance with a small area isused as heater. Two high ohmic resistors on the left and right hand side of the heater are used to detect the flow-
speed and flow direction. A further resistance allows the measurement of the gas temperature.
The two resistors close to the heater can be connected in a bridge circuit. This leads in an output
signal which is a function of flow speed and direction. In no flow condition, these two resistors are heated up equally. If flow appears, one of them is cooled more than the other, depending on flow direction.
The temperature difference can be measured and depends on flow speed and direction. Response and heating up time of this flow sensor is very short due to the small thermal mass. This kind of evaluation allows the measurement of very low flow speeds. In order to detect higher flow velocities, the temperature sensor can be connected in a constant-temperature-anemometer.
Advantages
Detection of flow direction
Small mass flows
Simple signal processing and calibration
No moved mechanical components
Excellent reproducibility
Excellent long-term stability
Easy adaptable for different applications or into housings
Best price-performance ratio
Applications
Differential pressure sensors
HVAC and building control solutions
Medical devices
Automotive industry
Device monitoring   Technical Data
Measuring principle Thermal
Measuring range 0 ... 50 m/s (in CTA-mode as electronic circuit example)
Response sensitivity 0.001 m/s
Accuracy < 2% measured value (depends on electronic and calibration)
Response time t63% < 0.5 s
Temperature range -20 ... +150 °C
Electrical connection Cu - wires enamel- insulated (typical length 25 mm)
Heater RH (25°C) = 34 ± 10%
Measuring elements Rs_i (25°C) = 425 ± 10%
Reference element RR (25°C) = 710 ± 10%
Required voltages Typical 2 … 5 V (depends on air velocity)
Substrate material Ceramic with low thermal conductivity
In general Higher requirements on request         Contact :  

Send your message to this supplier

  • Ms. Yan

  • Enter between 20 to 4,000 characters.