shenzhen lydian technology Co.,Limited
shenzhen lydian technology Co.,Limited
Wall Mounted Combined Co / Carbon Monoxide And Gas Detector
  • Wall Mounted Combined Co / Carbon Monoxide And Gas Detector
Wall Mounted Combined Co / Carbon Monoxide And Gas Detector

Wall Mounted Combined Co / Carbon Monoxide And Gas Detector

Min. Order:
1
Min. Order:
1
Delivery Time:
30 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen, China
Product Description
Product Description


Wall Mounted Combined Co / Carbon Monoxide And Gas Detector For Natural Gas LYD-710DVF

Description:

The product is wall mounted combined Co and gas detector with high stability,
it is used for detecting leaking gas and Co. Advanced semiconductor sensor is adopted to
ensure high stability and long life. It is convenient for mounting. The product is suitable for
the safety of residential house, villas, hotels, markets, boarding house etc.

Features:

* Detects Natural Gas, and Coal Gas etc. Combustible Gases, Carbon Monoxide

* Sound and Flash Alarm

* Auto-Check Sensor Failure

* Auto Charge Backup Battery

* Long Lifespan (5 years) Semiconductor Sensor with High Stability

* Advance Microprocessor Technology

* Auto Reset after Leaked Gas and Co Clears

* Different CO and Gas Alarm Audios

* 12V Pulse Output to Drive Solenoid Valve / Electrovalve to Shut Off Gas Pipe Supply
* Normally Open Relay Output to Drive Exhaust Fan to Clear Leaked Gas

* 24-48 Hours Aging Tests of both PCBA and Finished Detectors

Specifications:

Working Voltage

AC110-240V + 9V back-up battery

Rated Power

≤3W

Warm-up Time

3-5 Minutes

Working Temp. Range

-10°c ~ +50 °c

Humidity Range

10% ~ 95% Relative Humidity (RH)

Alarm Level

CO 150PPM ±80PPM
natural Gas: 10%±5%LEL(5000PPM±2500PPM)

Alarm Reset

Automatic Reset after CO or Gas Clears

Sensor

CO Sensor: Semiconductor; Gas Sensor: Semiconductor

Indicator Information

AC Power: Constant Green Light ON
Alarm: RED Light Rapidly Flashing
Sensor Fault: Constant Yellow Light

Alarm Output

85dB at 10 feet
Gas Alarm: Continuous Beeps
Carbon Monoxide Alarm: 3 beeps, pause, 3beeps
N.O. Relay Output/12V Pulse Output

Alarm Sensitivity

<10% LEL

Dimension

118.5 x 82 x 43mm

12V Pulse Output to Drive Solenoid Valve to shut off CO supply
Normally Open Relay Output to Drive Exhaust Fan to clear Leaked CO

Competitive Advantage:

* Professional experience and ability to accept and fulfill ODM/OEM orders.

* Answer your enquiries, questions and emails in 24 hours

* Direct control on material, testing, quality, lead time ect.

* Flexible Payment terms ranged at different quantity

* One year warranty life for all detectors sold out from Lydian

Send your message to this supplier

  • Ms. Ms. Jane Law

  • Enter between 20 to 4,000 characters.