LCD Custom 1 Channel 800A, 50Hz Programmable M60 Protection Controller / Motor Protection Relay

Profile

M60 protection controller is designed to provide full-scale protections and controls of low-voltage asynchronous motor and increasing safety motor rated below 800A, 50Hz, 380VAC. M60 measures the electrical parameters of motors, operates and controls the motors ,and equipped with the history record management and remote communication function.

M60 products portfolio: standard M60-1S and M60-3S, popular M60-2M and integrated M60-2P. With different infrastructure, installation, and functions, these four types of protector controllers can meet different requirements of customers in low-voltage protection area.

Features

Variety of product portfolio to suit customers' needs

Recording function to record the instant data before and after the faults for fault analysis purpose

Flexible protection functions configuration to ensure the safe and continuous production

Automatic software and hardware inspection to increase the stability and reliability

Remote or local operation on parameters setup, motor start, stop, and reset

Detection on the motor start status automatically to avoid malfunction

Configured with large size LCD panel for on-site operation (optional)

Technical Specification of M60-1S

Input (M60-1S)

Input Current: 5A

Remote digital signal input: 1 channel (dry contact)

Output (M60-1S)

RS-485 output: 1 channel

Analog output: M60-1S, 1 channel (4-20mA or 0-5V)

Relay output: 2 channels (dry contact)

Contact capacity of control output relay: 10A/250VAC

Contact capacity of alarm output relay: 10A/250VAC

Measurement Record (M60-1S)

Accuracy: I, class 0.5

Accumulated operating time on record (Max.): 9999days

Size & Weight: (M60-1S)

Installation: Panel mounting

Dimensional size: 96mmX48mmX76mm

Installation size: 94mmX46mm

Weight: 450g

Environment

Auxiliary power supply: 85~265VAC/DC

Total power consumption: <3VA(M60-1S/3S )

Operation temperature: -20℃ ~ +60℃

Storage temperature: -40℃ ~ +85℃

Operation humidity: <90%RH

Storage humidity: <95%RH

Protection Function:

Function

Status

Item

Content

M60-1S

M60-2S

M60-2M

M60-2P

Overtime start

protection

Programmable

Allowed

startup time

0-80s

Yes

Yes

Yes

Yes

Protection

method

2

Short circuit protection

Programmable

Fault setting

range

4-12le

Yes

Yes

Yes

Yes

Execution

delay time

0.1-0.5s

Protection

method

0, 2

Locked rotor protection

Programmable

Fault setting

range

200-950%le

Yes

Yes

Yes

Yes

Warning

setting

range

150-255%le

Execution

delay time

0.1-25.5s

Protection

method

0, 1, 2, 4

Underload protection

Programmable

Setting

range

20-95%le

Yes

Yes

Yes

Yes

Execution

delay time

0.1-60s

Protection

method

0, 1, 2, 3

Overload protection

Programmable

Setting range

105-150%le

Yes

Yes

Yes

Yes

Execution

delay time

0.1-250s

Protection

method

0, 1, 2, 3, 4

Thermal by overload

Must

Setting

range

1-105%θb

Yes

Yes

Yes

Yes

Protection

method

4

tE time protection

(Increased Safty Motor)

Programmable

tE time

1.0-15s

Yes

Yes

Yes

Yes

Protection

method

4

Unbalance protection

(phase failure)

Programmable

Setting range

10%-60%

Yes

Yes

Yes

Yes

Execution

delay time

0.1-30s

Protection

method

0, 2, 4

Over power

protection

Programmable

Setting

range

101-120%Pe

Yes

Yes

Execution

delay time

0.1-200s

Protection

method

0, 1, 2, 3

Under power

protection

Programmable

Setting range

30-80%Pe

Yes

Yes

Execution

delay time

0.1-200s

Protection

method

0, 1, 2, 3

Over power

factor protection

Programmable

Setting range

0.01-1.00

Yes

Yes

Execution

delay time

0.1-25.5s

Protection

method

0, 1, 2, 3

Under power

factor protection

Programmable

Setting range

0.01-1.00

Yes

Yes

Execution

delay time

0.1-25.5s

Protection

method

0, 1, 2, 3

Phase reversal

protection

Porgrammable

Execution

delay time

0.1-25.5s

Yes

Yes

Protection

method

0, 2

Under voltage

protection

Programmable

Setting range

45-95%Ue

Yes

Yes

Execution

delay time

0.1-200s

Protection

method

0, 1, 2, 3

Over voltage

protection

Programmable

Setting range

101-120%Ue

Yes

Yes

Execution

delay time

0.1-200s

Protection

method

0, 1, 2, 3

Leakage Current

protection

Programmable

Setting range

10-500mA

Yes

Yes

Execution

delay time

0.1-5s

Protection

method

0, 1, 2

Overheat

protection

Programmable

Execution

delay time

0.5s

Yes

Protection

method

0, 2

Interlock

protection

Programmable

Execution

delay time

0.1-60s

Yes

Yes

Yes

Yes

Protection

method

2

Connection to

ground protction

Programmable

Setting range

10-100%Ie

Yes

Yes

Yes

Yes

Execution

delay time

0.1-5s

Protection

method

0, 2

M60-1S

M60-3S

M60-2M

M60-2P

Control function

Direct start

Reversing start

Y-△Start

Lower Voltage start

Restart motors caused by Voltage fluctuation

Emergency fault output

Local/remote command of start, stop

Measurement function

Operating Current

Unbalanced Current ratio

Voltage, frequency, power, power factor,leakage current

No. of contact executions

Status of contacts

Record Function

Latest 10 start/stop record

Clock

Clock

Latest 10 alarm record

No clock

No clock

Clock

Clock

Latest 10 trip record

No clock

No clock

Clock

Clock

Latest 10 restart record caused by Voltage fluctuation

Clock

Clock

Max. and min. parameters records in the protection execution

Accumulated operating time of motor

Communication Function

RS-485 com. Port

Modbus protocol

Profibus protocol

Remark:

M60-3S performs the same function as M60-1S, except that M60-3S has built-in CT, M60-1S has exterior

CT with 5A input.

Competitive advantage :


We can follow the Customer-oriented principle, Artel Tech. aims to innovate hi-tech products and provide comprehensive solutions continuously, and continue to offer qualified products and excellent services to its global customers.

Artel's successful strategy is reflected in the number of certifications, including ISO9001 and CE quality system certification, Software Enterprise certificate issued by National Information Department, and hi-tech company certificate issued by government, etc.

Send your message to this supplier

  • Ms. Miss. Maple

  • Enter between 20 to 4,000 characters.