12-inch Fetal Monitor CTG Machine with Tocodynagraph, Phonocardiograph and Printer, CE-certified
- Payment Type:
- 100% T/T in Advance, PayPal, Western Union, L/C
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | 100% T/T in Advance, PayPal, Western Union, L/C |
---|
Product Description
Product Description
- 12.1-inch high resolution color TFT LCD display, supports plug-in large screen CRT display
- Standard configurations: FHR, TOCO, fetal movement, ECG, Spo2, NIBP, RESP, TEMP and pulse rate
- Optional twins
- Portable and convenient monitor
- Built-in rechargeable Li-ion battery, AC/DC power supply, without interruption monitor
- Dynamic save and display monitoring information within 48 hours
- Support extension almost for 128 units central monitor system
- Quality speaker take more clear and loud sound
- FHR:
- Ultrasound probe: 12 pieces chip, multiple wafer, wave-beam and high sensitive
- Ultrasound frequency: 1MHz ±5%
- Ultrasound intensity: <3 mW/cm2
- FHR range: 30 to 240bpm
- Resolution: 1bpm
- Accuracy: ±1bpm/1%
- TOCO:
- TOCO range: 0 to 100 (relative unit)
- Resolution: 1bpm
- Non-linear error: ≤±5%
- Fetal movement: button hand count (automatic cumulative number of movements)
- NIBP:
- Measurement units: mmHg/kPa are optional
- Pressure protection: double security protection software and hardware
- Work mode: auto and manual
- Measurement intervals: 2 to 60 minutes setup
- Survey:
- Systolic blood pressure: 60 to 240mmHg
- Average blood pressure: 40 to 200mmHg
- Diastolic blood pressure: 30 to 180mmHg
- Resolution: 1mmHg
- Accuracy: ±3mmHg
- Pulse rate: 40 to 240bpm
- SPO2:
- Range: 70 to 99%
- Resolution: 1%
- Accuracy: ±2 effective digital
- Pulse rate range: 40 to 240bpm
- ECG:
- Range: 30 to 300bpm
- Accuracy: ±1bpm/1%
- Choices: I, II, III, aVR, aVL, aVF and V
- Scan speeds: 12.5, 25 and 50mm/s
- Gain choices: x0.25, x0.5, x1 and x2
- Applications: diagnosis, monitor and surgery
- Respiration:
- Range: 1 to 99rpm
- Resolution: 1rpm
- Accuracy: ±2rpm
- Printer: 152mm usual thermal paper and more economical
- Ultrasound probe: 12 pieces chip, multiple wafer, wave-beam and high sensitive
- Ultrasound frequency: 1MHz ±5%
- Ultrasound intensity: <3 mW/cm2
- FHR range: 30 to 240bpm
- Resolution: 1bpm
- Accuracy: ±1bpm/1%
- TOCO range: 0 to 100 (relative unit)
- Resolution: 1bpm
- Non-linear error: ≤±5%
- Measurement units: mmHg/kPa are optional
- Pressure protection: double security protection software and hardware
- Work mode: auto and manual
- Measurement intervals: 2 to 60 minutes setup
- Survey:
- Systolic blood pressure: 60 to 240mmHg
- Average blood pressure: 40 to 200mmHg
- Diastolic blood pressure: 30 to 180mmHg
- Resolution: 1mmHg
- Accuracy: ±3mmHg
- Pulse rate: 40 to 240bpm
- Range: 70 to 99%
- Resolution: 1%
- Accuracy: ±2 effective digital
- Pulse rate range: 40 to 240bpm
- Range: 30 to 300bpm
- Accuracy: ±1bpm/1%
- Choices: I, II, III, aVR, aVL, aVF and V
- Scan speeds: 12.5, 25 and 50mm/s
- Gain choices: x0.25, x0.5, x1 and x2
- Applications: diagnosis, monitor and surgery
- Range: 1 to 99rpm
- Resolution: 1rpm
- Accuracy: ±2rpm
- Systolic blood pressure: 60 to 240mmHg
- Average blood pressure: 40 to 200mmHg
- Diastolic blood pressure: 30 to 180mmHg
- Resolution: 1mmHg
- Accuracy: ±3mmHg