  • Description:
    • 9 and 12V stand-alone network based both lines, smoke detector temperature compound, ceiling or wall mounting, flash alarm indicator, test button for easy recommended monthly testing, low battery signal, safety clip feature, photoelectric chamber for early detection from all directions 85dB
  • Features:
    • Photoelectric sensor
    • Alarm temperature for heat sensor: adjustable (maximum 58°C)
    • Red LED indicate alarm
    • Unique battery missing lockout
    • Low battery alarm
    • High sensitivity
    • Built in sounder to give a minimum sound output of 85dB at 3m
    • Senses smoke using the light scatter principle-quick response to visible smouldering smoke, test button simulates smoke use to check performance at least monthly, option current ≤10uA, alarm current ≤30mA
  • Name: dust protection and insect nets smoke/heat alarm/detector (TA-2688)
  • Model: TA-2688
  • Power source: 9V DC battery
  • Operating current: 10uA (normal) and 20-50mA
  • Sensitivity to smoke: compliant with UL217
  • Operating temperature: 4.4 - 37.8°C
  • Ambient humidity: 10 - 90%
  • Horn level: 85dB at 10ft
  • Battery life: 1 year (minimum)
  • Size: 110x25mm
  • 9 and 12V stand-alone network based both lines, smoke detector temperature compound, ceiling or wall mounting, flash alarm indicator, test button for easy recommended monthly testing, low battery signal, safety clip feature, photoelectric chamber for early detection from all directions 85dB
  • Photoelectric sensor
  • Alarm temperature for heat sensor: adjustable (maximum 58°C)
  • Red LED indicate alarm
  • Unique battery missing lockout
  • Low battery alarm
  • High sensitivity
  • Built in sounder to give a minimum sound output of 85dB at 3m
  • Senses smoke using the light scatter principle-quick response to visible smouldering smoke, test button simulates smoke use to check performance at least monthly, option current ≤10uA, alarm current ≤30mA