Shenzhen Fanhai Sanjiang Electronics Co. Ltd
Shenzhen Fanhai Sanjiang Electronics Co. Ltd
Addressable Fire Alarm Control System with Less Than 324 Addresses and 120W AC Input Power
  • Addressable Fire Alarm Control System with Less Than 324 Addresses and 120W AC Input Power
Addressable Fire Alarm Control System with Less Than 324 Addresses and 120W AC Input Power

Addressable Fire Alarm Control System with Less Than 324 Addresses and 120W AC Input Power

Payment Type:
100% Payment in Advance
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: 100% Payment in Advance
Product Description
Product Description
  • There are 3 types of addressable fire alarm control panels:
    • JB-QBL-MN/300-100: 100 addresses
    • JB-QBL-MN/300-200: 200 addresses
    • JB-QBL-MN/300-324: 324 addresses
  • The MN/300 series have the following detectors and accessories:
    • JTY-GD-930: addressable photoelectric smoke detector
    • JTW-ZD-920: addressable fixed temperature heat detector
    • J-SAP-M-960: addressable manual call point
    • SG-991: addressable hooter/horn
    • JK-952: addressable input module
    • KZJ-956: addressable output module
    • CODER-F189: coder for setting address
    • The MN/300 series is an economic, reliable, and user-friendlysystem
  • Product features of JB-QBL-MN/300:
    • The JB-QBL-MN/300 is a new type of analog fire alarm control panel which has 324 alarm control points (detectors and modules which are characterized by fully mixed coding, non-polarity and two buses)
    • It complies with the provisions of both fire alarm control units (GB4717-2005) and automatic control system for fire protection (GB16806-2006)
  • Technical parameters of JB-QBL-MN/300:
    • Capacity: 324 points (non-polarity, two wire bus, fully mixed coding)
    • AC input voltage: 220V AC ± 20%, 50Hz
    • AC input power: 120W
    • DC power: 24V DC, 5.0Ah, two fully sealed maintenance-free12V/5.0Ah storage batteries connected in series
    • The 24V DC power has a long-term constant output current of6A
    • The 5V DC power has a long-term constant output current of4A
    • Circuit bus: two-wire system
    • Total length: d1500m
    • Voltage UL of the circuit bus:
      • +20V dUL d+26V (when the DC power is operating)
      • +24VdULd+26V (when the AC power is operating)
    • System working conditions
    • Temperature: -10 to +50
    • Humidity: d95%
    • Power supply: 220V AC/50Hz, 24V DC/6A
    • Output contact capacity: 220V DC/1A, 27.6V DC/3A
    • Size: 460 x 330 x 100mm
    • See the specifications of detectors and modules for the specific technical parameters of the detectors, the interface module, the monitoring module and the control module
  • JB-QBL-MN/300-100: 100 addresses
  • JB-QBL-MN/300-200: 200 addresses
  • JB-QBL-MN/300-324: 324 addresses
  • JTY-GD-930: addressable photoelectric smoke detector
  • JTW-ZD-920: addressable fixed temperature heat detector
  • J-SAP-M-960: addressable manual call point
  • SG-991: addressable hooter/horn
  • JK-952: addressable input module
  • KZJ-956: addressable output module
  • CODER-F189: coder for setting address
  • The MN/300 series is an economic, reliable, and user-friendlysystem
  • The JB-QBL-MN/300 is a new type of analog fire alarm control panel which has 324 alarm control points (detectors and modules which are characterized by fully mixed coding, non-polarity and two buses)
  • It complies with the provisions of both fire alarm control units (GB4717-2005) and automatic control system for fire protection (GB16806-2006)
  • Capacity: 324 points (non-polarity, two wire bus, fully mixed coding)
  • AC input voltage: 220V AC ± 20%, 50Hz
  • AC input power: 120W
  • DC power: 24V DC, 5.0Ah, two fully sealed maintenance-free12V/5.0Ah storage batteries connected in series
  • The 24V DC power has a long-term constant output current of6A
  • The 5V DC power has a long-term constant output current of4A
  • Circuit bus: two-wire system
  • Total length: d1500m
  • Voltage UL of the circuit bus:
    • +20V dUL d+26V (when the DC power is operating)
    • +24VdULd+26V (when the AC power is operating)
  • System working conditions
  • Temperature: -10 to +50
  • Humidity: d95%
  • Power supply: 220V AC/50Hz, 24V DC/6A
  • Output contact capacity: 220V DC/1A, 27.6V DC/3A
  • Size: 460 x 330 x 100mm
  • See the specifications of detectors and modules for the specific technical parameters of the detectors, the interface module, the monitoring module and the control module
  • +20V dUL d+26V (when the DC power is operating)
  • +24VdULd+26V (when the AC power is operating)
  • Send your message to this supplier

    • Mr.  David Supervisor

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords