Patient Monitor Accurate Measurement, Ideal for ECG
- Payment Type:
- Telegraphic Transfer in Advance (Advance TT, T/T)
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | Telegraphic Transfer in Advance (Advance TT, T/T) |
---|
Product Description
Product Description
- Drug calculation, ST segment detection, pacemaker andarrhythmia analysis
- 5 types of fixed display format includes OxyCRG diagram, 7 leadECG waveform simultaneously and large font mode
- 5 types of user defined display format: display multichannelreal-time waveform and trend diagram same time
- Audible/visual alarm, apnea alarm available, alarm limits areadjustable
- WAN communication function to network with central monitoringsystem, make long distance monitoring, diagnosis, maintenance andsoftware upgrade possible
- Printing of data, waveform, trend table and trend diagram
- Complete carting and mounting solution
- Suitable for adults, pediatrics and neonates
- Applications in bedside/delivery monitoring: widely used inpatient room, emergency room, PACU, ICU and CCU
- Huge history trend data storage: up to 360 hours
- ECG:
- Input: 3/5 wires ECG cable
- Lead section: I, II, III/ aVR, aVL and aVF/V
- Gain section: x1/4, x1/2, x1, x2 and x4, automatic
- Sweep speed: 6.25, 12.5, 25 and 50mm/s
- Heart rate range: 15 to 380BPM
- Calibration: ±1mV
- SpO2:
- Display type: waveform, data
- Measurement range: 0 to 100%
- Accuracy: ± 2%
- Pulse measurement range: 30 to 250BPM
- Resolution: ±1BPM
- NIBP:
- Philosophy: oscillometric method
- Measurement type: adult, pediatric, neonate
- Measurement parameter: systolic, diastolic and mean
- Measurement method: manual, automatic and continuousmeasurement
- Unit: mmHg/kPa selectable
- Accuracy: ±2 or 3mmHg
- Temperature:
- Number of channel: 2 channels
- Resolution: 0.1°C
- Display: T1, T2 and ΔT
- Respiration:
- Thoracic impedance, nasal tube double
- Method delectable
- Measurement range: 0 to 120BPM
- Accuracy: ±1BPM
- Resolution: 1BPM
- ETCO2:
- Main/side stream (optional): Plug-and-play
- Measurement range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
- Accuracy: ±2mmHg
- Respiration rate: 0 to 150BrPM
- Accuracy: ±1BrPM
- Input: 3/5 wires ECG cable
- Lead section: I, II, III/ aVR, aVL and aVF/V
- Gain section: x1/4, x1/2, x1, x2 and x4, automatic
- Sweep speed: 6.25, 12.5, 25 and 50mm/s
- Heart rate range: 15 to 380BPM
- Calibration: ±1mV
- Display type: waveform, data
- Measurement range: 0 to 100%
- Accuracy: ± 2%
- Pulse measurement range: 30 to 250BPM
- Resolution: ±1BPM
- Philosophy: oscillometric method
- Measurement type: adult, pediatric, neonate
- Measurement parameter: systolic, diastolic and mean
- Measurement method: manual, automatic and continuousmeasurement
- Unit: mmHg/kPa selectable
- Accuracy: ±2 or 3mmHg
- Number of channel: 2 channels
- Resolution: 0.1°C
- Display: T1, T2 and ΔT
- Thoracic impedance, nasal tube double
- Method delectable
- Measurement range: 0 to 120BPM
- Accuracy: ±1BPM
- Resolution: 1BPM
- Main/side stream (optional): Plug-and-play
- Measurement range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
- Accuracy: ±2mmHg
- Respiration rate: 0 to 150BrPM
- Accuracy: ±1BrPM
Related Keywords
Related Keywords