Idealink Network Technology Co.,Ltd
Idealink Network Technology Co.,Ltd
CAT6 LAN Cable UTP 24 AWG Pure Copper, Working to 100m PVC, RoHS Mark, Pass Fluke Test
  • CAT6 LAN Cable UTP 24 AWG Pure Copper, Working to 100m PVC, RoHS Mark, Pass Fluke Test
  • CAT6 LAN Cable UTP 24 AWG Pure Copper, Working to 100m PVC, RoHS Mark, Pass Fluke Test
CAT6 LAN Cable UTP 24 AWG Pure Copper, Working to 100m PVC, RoHS Mark, Pass Fluke Test
CAT6 LAN Cable UTP 24 AWG Pure Copper, Working to 100m PVC, RoHS Mark, Pass Fluke Test

CAT6 LAN Cable UTP 24 AWG Pure Copper, Working to 100m PVC, RoHS Mark, Pass Fluke Test

Payment Type:
Telegraphic Transfer (TT, T/T)
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: Telegraphic Transfer (TT,T/T)
Product Description
Product Description
  • Specifications:
    • Conductor: solid bare copper
    • Conductor diameter: 0.56mm
    • Insulation: PE
    • Average thickness (±0.03mm): 0.22mm
    • Minimum point thickness: 0.18mm
    • Insulation diameter (±0.03mm): 1.02mm
    • Twisted lay length: 30mm (underneath)
    • Cabling lay length: 200mm (underneath)
    • Average thickness: 0.5mm
    • Minimum point thickness: 0.43mm
    • Outer diameter (±1.00mm): 6.0mm
    • Rip cord: supported
    • Weight (normal): 42kg/km
    • Core colors:
      • Pair 1: blue white/blue
      • Pair 2: orange white/orange
      • Pair 3: green white/orange
      • Pair 4: brown white/brown
  • Electrical performance (at 250MHz):
    • 1.0 to 100.0MHz with impedance of 100Ω ±15
    • 100.0 to 250.0MHz with impedance of 100Ω ±22
    • Impedance delay screw: <45ns/100m
    • Pair to ground capacitance unbalance: 330pF/100m (maximum)
    • Conductor DC resistance 20%: <73.2Ω/km
    • Resistance unbalance: 5%
    • Test object: jacket
    • Test material: PVC
    • Before tensile strength: ≥13.8MPa
    • Aging elongation: ≥100%
    • Aging condition (c x hours): 100 x 240
    • After tensile strength: ≥85%MPa of unaged
    • Aging elongation: ≥50% of aged
    • Cold bend (-20 ±2°C x 4 hours): no crack
  • LAN cable standard compliance:
    • All proposed category 6 requirement as per ANSI/TIA/EIA, ISO/IEC and Cenelec EN standards
    • ANSI/TIA/EIA 568-B.2-1 Cat6
    • ISO/IEC 11801 class E 2nd edition
    • Cenelec EN 61156-6
    • Cenelec EN 50173-1
    • Cenelec EN 50288-5-1
    • Cenelec EN 50288-5-2
    • Flame-retardant is verified according to IEC 60332-1-2
  • OEM service:
    • Conductor: solid bare copper/CCS/CCA
    • AWG: 23/24
    • Insulation: foam PE/solid PE
    • Jacket: PVC/LSZH
  • Applications:
    • Pots T1/T1 fractional, ISDN basic and primary rate
    • 4/16Mbps token ring (IEEE 802.5) 10base-T (IEEE802.5)
    • 100Mbps TP-PMD.52/155Mbps ATM (ATM forum)
    • 100base-T4 (fast Ethernet)
    • 100VG-any LAN (IEEE802.12)
    • 100baseT-T (fast Ethernet)
    • 1Gbps Ethernet (IEEE802.3)
  • Packaging: wooden roller
  • Conductor: solid bare copper
  • Conductor diameter: 0.56mm
  • Insulation: PE
  • Average thickness (±0.03mm): 0.22mm
  • Minimum point thickness: 0.18mm
  • Insulation diameter (±0.03mm): 1.02mm
  • Twisted lay length: 30mm (underneath)
  • Cabling lay length: 200mm (underneath)
  • Average thickness: 0.5mm
  • Minimum point thickness: 0.43mm
  • Outer diameter (±1.00mm): 6.0mm
  • Rip cord: supported
  • Weight (normal): 42kg/km
  • Core colors:
    • Pair 1: blue white/blue
    • Pair 2: orange white/orange
    • Pair 3: green white/orange
    • Pair 4: brown white/brown
  • Pair 1: blue white/blue
  • Pair 2: orange white/orange
  • Pair 3: green white/orange
  • Pair 4: brown white/brown
  • 1.0 to 100.0MHz with impedance of 100Ω ±15
  • 100.0 to 250.0MHz with impedance of 100Ω ±22
  • Impedance delay screw: <45ns/100m
  • Pair to ground capacitance unbalance: 330pF/100m (maximum)
  • Conductor DC resistance 20%: <73.2Ω/km
  • Resistance unbalance: 5%
  • Test object: jacket
  • Test material: PVC
  • Before tensile strength: ≥13.8MPa
  • Aging elongation: ≥100%
  • Aging condition (c x hours): 100 x 240
  • After tensile strength: ≥85%MPa of unaged
  • Aging elongation: ≥50% of aged
  • Cold bend (-20 ±2°C x 4 hours): no crack
  • All proposed category 6 requirement as per ANSI/TIA/EIA, ISO/IEC and Cenelec EN standards
  • ANSI/TIA/EIA 568-B.2-1 Cat6
  • ISO/IEC 11801 class E 2nd edition
  • Cenelec EN 61156-6
  • Cenelec EN 50173-1
  • Cenelec EN 50288-5-1
  • Cenelec EN 50288-5-2
  • Flame-retardant is verified according to IEC 60332-1-2
  • Conductor: solid bare copper/CCS/CCA
  • AWG: 23/24
  • Insulation: foam PE/solid PE
  • Jacket: PVC/LSZH
  • Pots T1/T1 fractional, ISDN basic and primary rate
  • 4/16Mbps token ring (IEEE 802.5) 10base-T (IEEE802.5)
  • 100Mbps TP-PMD.52/155Mbps ATM (ATM forum)
  • 100base-T4 (fast Ethernet)
  • 100VG-any LAN (IEEE802.12)
  • 100baseT-T (fast Ethernet)
  • 1Gbps Ethernet (IEEE802.3)
  • Send your message to this supplier

    • Ms.  Sophie

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords