Digital Temperature Controller Module, -9 to 99°C
- Payment Type:
- L/C, T/T, Western Union or PayPal
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Payment Type: | L/C, T/T, Western Union or PayPal |
---|
Product Description
Product Description
- High temperature start:
- Set the starting temperature value to ">", stop temperature value
- When the detected temperature is "≥", start temperature, the relay is closed, refrigeration equipment work
- When the detected temperature is "≤", stop temperature, the relay off, refrigeration equipment stops working.
- For example: set the starting temperature to 30°C, stop temperature is 25°C
- When the detected temperature is "≥30°C", the relay is closed, the start indicator (red) lights
- When the detected temperature is value "≤25°C", the relay off, stop indicator (green) light
- Cold start:
- Start temperature set value
- When the detected temperature is "≤", start temperature relay is closed, the heating device operates
- When the detected temperature is "≥" stop temperature, the relay is off, the heating device is stopped
- For example: set the starting temperature to 25°C, stop temperature is 30°C,
- When the detected temperature value is ≤25°C, the relay is closed, the start indicator is (red) lights
- When the detected temperature is ≥30°C, the relay is off, stop indicator (green) light
- Set to start when the temperature value is "= stop temperature value", the relay is off
- Set the starting temperature value to ">", stop temperature value
- When the detected temperature is "≥", start temperature, the relay is closed, refrigeration equipment work
- When the detected temperature is "≤", stop temperature, the relay off, refrigeration equipment stops working.
- For example: set the starting temperature to 30°C, stop temperature is 25°C
- When the detected temperature is "≥30°C", the relay is closed, the start indicator (red) lights
- When the detected temperature is value "≤25°C", the relay off, stop indicator (green) light
- Start temperature set value
- When the detected temperature is "≤", start temperature relay is closed, the heating device operates
- When the detected temperature is "≥" stop temperature, the relay is off, the heating device is stopped
- For example: set the starting temperature to 25°C, stop temperature is 30°C,
- When the detected temperature value is ≤25°C, the relay is closed, the start indicator is (red) lights
- When the detected temperature is ≥30°C, the relay is off, stop indicator (green) light
- Set to start when the temperature value is "= stop temperature value", the relay is off
Related Keywords