Shenzhen Chairman Electronic Co. Ltd
Shenzhen Chairman Electronic Co. Ltd
Digital Temperature Controller Module, -9 to 99°C
  • Digital Temperature Controller Module, -9 to 99°C
  • Digital Temperature Controller Module, -9 to 99°C
  • Digital Temperature Controller Module, -9 to 99°C
  • Digital Temperature Controller Module, -9 to 99°C
  • Digital Temperature Controller Module, -9 to 99°C
Digital Temperature Controller Module, -9 to 99°C
Digital Temperature Controller Module, -9 to 99°C
Digital Temperature Controller Module, -9 to 99°C
Digital Temperature Controller Module, -9 to 99°C
Digital Temperature Controller Module, -9 to 99°C

Digital Temperature Controller Module, -9 to 99°C

Payment Type:
L/C, T/T, Western Union or PayPal
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: L/C, T/T, Western Union or PayPal
Product Description
Product Description
  • Digital temperature controller module
  • DC 12V intelligent digital display thermostat temperature controller
  • Temperature range: -9 - 99°C
  • Accuracy: 1°C
  • Control accuracy: 1°C
  • Setting range: -9 - 99°C
  • Refresh rate: 0.5S
  • Input power: DC 12V
  • Output: relay output (capacities: 220V 10A/12V 10A)
  • Environmental requirements: -10 - 60°C
  • Humidity: 20% -85%
  • Size: 78x51mm
  • Temperature sensor: NTC (3950-10k 1%)
  • Applicable for various spatial temperature control, water temperature control, incubators and more
  • Operating instructions:
    • High temperature start:
      • Set the starting temperature value to ">", stop temperature value
      • When the detected temperature is "≥", start temperature, the relay is closed, refrigeration equipment work
      • When the detected temperature is "≤", stop temperature, the relay off, refrigeration equipment stops working.
      • For example: set the starting temperature to 30°C, stop temperature is 25°C
      • When the detected temperature is "≥30°C", the relay is closed, the start indicator (red) lights
      • When the detected temperature is value "≤25°C", the relay off, stop indicator (green) light
    • Cold start:
      • Start temperature set value
      • When the detected temperature is "≤", start temperature relay is closed, the heating device operates
      • When the detected temperature is "≥" stop temperature, the relay is off, the heating device is stopped
      • For example: set the starting temperature to 25°C, stop temperature is 30°C,
      • When the detected temperature value is ≤25°C, the relay is closed, the start indicator is (red) lights
      • When the detected temperature is ≥30°C, the relay is off, stop indicator (green) light
      • Set to start when the temperature value is "= stop temperature value", the relay is off
  • High temperature start:
    • Set the starting temperature value to ">", stop temperature value
    • When the detected temperature is "≥", start temperature, the relay is closed, refrigeration equipment work
    • When the detected temperature is "≤", stop temperature, the relay off, refrigeration equipment stops working.
    • For example: set the starting temperature to 30°C, stop temperature is 25°C
    • When the detected temperature is "≥30°C", the relay is closed, the start indicator (red) lights
    • When the detected temperature is value "≤25°C", the relay off, stop indicator (green) light
  • Cold start:
    • Start temperature set value
    • When the detected temperature is "≤", start temperature relay is closed, the heating device operates
    • When the detected temperature is "≥" stop temperature, the relay is off, the heating device is stopped
    • For example: set the starting temperature to 25°C, stop temperature is 30°C,
    • When the detected temperature value is ≤25°C, the relay is closed, the start indicator is (red) lights
    • When the detected temperature is ≥30°C, the relay is off, stop indicator (green) light
    • Set to start when the temperature value is "= stop temperature value", the relay is off
  • Set the starting temperature value to ">", stop temperature value
  • When the detected temperature is "≥", start temperature, the relay is closed, refrigeration equipment work
  • When the detected temperature is "≤", stop temperature, the relay off, refrigeration equipment stops working.
  • For example: set the starting temperature to 30°C, stop temperature is 25°C
  • When the detected temperature is "≥30°C", the relay is closed, the start indicator (red) lights
  • When the detected temperature is value "≤25°C", the relay off, stop indicator (green) light
  • Start temperature set value
  • When the detected temperature is "≤", start temperature relay is closed, the heating device operates
  • When the detected temperature is "≥" stop temperature, the relay is off, the heating device is stopped
  • For example: set the starting temperature to 25°C, stop temperature is 30°C,
  • When the detected temperature value is ≤25°C, the relay is closed, the start indicator is (red) lights
  • When the detected temperature is ≥30°C, the relay is off, stop indicator (green) light
  • Set to start when the temperature value is "= stop temperature value", the relay is off
  • Send your message to this supplier

    • Mr.  Xiansheng

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords
    Product Categories