Product Description
Product Description
- High-reliability with industry standards
- Built-in over-voltage, over-current and short-circuitprotections
- Input:
- Voltage: 90 or 264V AC ±15%
- Frequency: 50/60Hz
- Maximum line regulation range: ±0.5
- Start up current: 40A at 230V AC
- Input current: 0.8A
- Output:
- Maximum line regulation range: ±0.5%
- Ripple and noise: <1% of output voltage
- Adjustable range of output voltage: 5 and -3%
- Start-up time: ≤1 seconds (AC input: 240V and IO: 100%)
- Hold-up time: ≥20 minutes (AC input: 240V and IO: 100%)
- Protection: overloading protection: 115 to 150% of ratedpower
- Over-voltage protections: 130 to 150% of rated voltage
- Short-circuit protection
- Withstand voltage:
- Input to output: 1,500V AC/5mA, 60 seconds
- Input to ground: 1,500V AC/5mA, 60 seconds
- Output to ground: 500V AC/5mA, 60 seconds
- Insulation resistance:
- Input to output: ≥50mΩ, 500V AC
- Input to ground: ≥50mΩ, 500V AC
- Output to ground: ≥50mΩ, 500V AC
- Environment requirement:
- Operating temperature: 0 to 40°C
- Operating humidity range: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity range: 10 to 95% RH (no freezing dew)
- Elevation: <3,000m
- Dimensions (L x W x H): 88 x 58 x 38mm
- Weight: 150g
- EMC: EN55022B and GB9254
- Voltage: 90 or 264V AC ±15%
- Frequency: 50/60Hz
- Maximum line regulation range: ±0.5
- Start up current: 40A at 230V AC
- Input current: 0.8A
- Maximum line regulation range: ±0.5%
- Ripple and noise: <1% of output voltage
- Adjustable range of output voltage: 5 and -3%
- Start-up time: ≤1 seconds (AC input: 240V and IO: 100%)
- Hold-up time: ≥20 minutes (AC input: 240V and IO: 100%)
- Protection: overloading protection: 115 to 150% of ratedpower
- Over-voltage protections: 130 to 150% of rated voltage
- Short-circuit protection
- Input to output: 1,500V AC/5mA, 60 seconds
- Input to ground: 1,500V AC/5mA, 60 seconds
- Output to ground: 500V AC/5mA, 60 seconds
- Input to output: ≥50mΩ, 500V AC
- Input to ground: ≥50mΩ, 500V AC
- Output to ground: ≥50mΩ, 500V AC
- Operating temperature: 0 to 40°C
- Operating humidity range: 10 to 90% RH (no freezing dew)
- Storage temperature: -20 to 85°C
- Storage humidity range: 10 to 95% RH (no freezing dew)