Product Description
Product Description
  • Features:
    • Universal input
    • Cooling by free air convection
    • Protections: short-circuit, OLP, OVP and OTP
    • IP00 or IP67
    • Design for indoor or outdoor use
    • Suitable for LED lighting and moving sign applications
    • Built-in active PFC function
    • PF: >0.9 for 75% loading or higher
    • UL1310 class 2 power unit and LPS design
    • Built-in CC mode function (optional)
    • Metallic case and enclosed type
  • Specifications:
    • Input voltages: 100-240V AC
    • Input frequency range: 50 to 60Hz
    • Input current: 5A (maximum)
    • Inrush current: 40A (maximum) (cold start)
    • Hold-up time: 10mS minute to nominal line
    • Output voltage: anywhere output 96W, V/DC
    • Loading regulation: ±5% (maximum)
    • Dielectric withstand:
      • I/P-O/P: 3,750V AC
      • I/P-FG: 1,880V AC
    • Operating temperatures: -20 to 60°C
    • Di-rating linearly from 100% loading at 50°C to 75% loadingat 60°C (for IP67)
    • Di-rating linearly from 100% loading at 40°C to 50% loadingat 60°C (for IP67)
    • Storage temperature: -40 to 85°C
    • Protections: OTP, OCP, OVP and short-circuit
    • Overload protections: 110 to 130% constant current limiting andauto-recovery
    • Safety standards: UL60950-1, UL1310 class 2, EN61347-1 andEN61347-2-13 (except for 48V)
    • EMC standards: EN55015, EN55022 class B and EN61000-3-2/-3-3,EN61000-4-2 3, 4, 5, 6, 8, 11 and EN61547
    • Standard output cable: UL-rated, 18 to 16#AWG
  • Universal input
  • Cooling by free air convection
  • Protections: short-circuit, OLP, OVP and OTP
  • IP00 or IP67
  • Design for indoor or outdoor use
  • Suitable for LED lighting and moving sign applications
  • Built-in active PFC function
  • PF: >0.9 for 75% loading or higher
  • UL1310 class 2 power unit and LPS design
  • Built-in CC mode function (optional)
  • Metallic case and enclosed type
  • Input voltages: 100-240V AC
  • Input frequency range: 50 to 60Hz
  • Input current: 5A (maximum)
  • Inrush current: 40A (maximum) (cold start)
  • Hold-up time: 10mS minute to nominal line
  • Output voltage: anywhere output 96W, V/DC
  • Loading regulation: ±5% (maximum)
  • Dielectric withstand:
    • I/P-O/P: 3,750V AC
    • I/P-FG: 1,880V AC
  • Operating temperatures: -20 to 60°C
  • Di-rating linearly from 100% loading at 50°C to 75% loadingat 60°C (for IP67)
  • Di-rating linearly from 100% loading at 40°C to 50% loadingat 60°C (for IP67)
  • Storage temperature: -40 to 85°C
  • Protections: OTP, OCP, OVP and short-circuit
  • Overload protections: 110 to 130% constant current limiting andauto-recovery
  • Safety standards: UL60950-1, UL1310 class 2, EN61347-1 andEN61347-2-13 (except for 48V)
  • EMC standards: EN55015, EN55022 class B and EN61000-3-2/-3-3,EN61000-4-2 3, 4, 5, 6, 8, 11 and EN61547
  • Standard output cable: UL-rated, 18 to 16#AWG
  • I/P-O/P: 3,750V AC
  • I/P-FG: 1,880V AC