Shenzhen Shanjing Power Supply Co. Ltd
Shenzhen Shanjing Power Supply Co. Ltd
CCTV power supply with UL, CE certificates, more than 80% efficiency, 60W
  • CCTV power supply with UL, CE certificates, more than 80% efficiency, 60W
CCTV power supply with UL, CE certificates, more than 80% efficiency, 60W

CCTV power supply with UL, CE certificates, more than 80% efficiency, 60W

Payment Type:
T/T
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T
Product Description
Product Description
  • 60W 24V, DC 2.5A medical power supply
  • More than 80% efficiency
  • Comes with plastic crust
  • Built-in over voltage, over-current and short-circuitprotection
  • Input:
    • Voltage: AC 100V-240V
    • Frequency: 50/60Hz
    • Line regulation range: 0.5 at maximum
    • Input current: less than 1.2A
    • Start-up current: 40A/230V AC
  • Output:
    • Line regulation range: 0.5% at maximum
    • Ripple and noise (mVp-p): <1% of output voltage
    • Adjustable range of output voltage: 5, -3%
    • Start-up time: at most one second (AC input 240V and IO =100%)
    • Hold-up time: at least 20ms (AC input 240V and IO = 100%)
  • Protection:
    • Overloading protection: 115% to 150% of rated power
    • Over-voltage protection: 130% to 150% of rated voltage
    • Short-circuit protection
  • Environmental requirements:
    • Operating temperature: 0 to 40°C
    • Operating humidity: 10 to 90% RH (no freezing dew)
    • Storage temperatures: -20 to 85°C
    • Storage humidity: 10 to 95% RH (no freezing dew)
    • Elevation: less than 3000m
  • Dimensions: 118 x 62 x 32mm
  • Weight: approximately 400g
  • EMC: EN55022B, GB9254
  • With CE, CCC, UL, and SAA certificates
  • Voltage: AC 100V-240V
  • Frequency: 50/60Hz
  • Line regulation range: 0.5 at maximum
  • Input current: less than 1.2A
  • Start-up current: 40A/230V AC
  • Line regulation range: 0.5% at maximum
  • Ripple and noise (mVp-p): <1% of output voltage
  • Adjustable range of output voltage: 5, -3%
  • Start-up time: at most one second (AC input 240V and IO =100%)
  • Hold-up time: at least 20ms (AC input 240V and IO = 100%)
  • Overloading protection: 115% to 150% of rated power
  • Over-voltage protection: 130% to 150% of rated voltage
  • Short-circuit protection
  • Operating temperature: 0 to 40°C
  • Operating humidity: 10 to 90% RH (no freezing dew)
  • Storage temperatures: -20 to 85°C
  • Storage humidity: 10 to 95% RH (no freezing dew)
  • Elevation: less than 3000m