Shenzhen Everbest Machinery Industry Co. Ltd
Shenzhen Everbest Machinery Industry Co. Ltd
Auto-ranging Digital Multimeter with Overload Protection and Indication
  • Auto-ranging Digital Multimeter with Overload Protection and Indication
Auto-ranging Digital Multimeter with Overload Protection and Indication

Auto-ranging Digital Multimeter with Overload Protection and Indication

Payment Type:
T/T before shipment or L/C at sight
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T before shipment or L/C at sight
Product Description
Product Description
  • Features:
    • Oversized high contrast 4000 counts backlight LCD display withdual display
    • Safety warning LCD-annunciator
    • Auto ranging
    • Data hold, auto power off and low battery indication
  • Specifications:
    • Measurement rate: 2 times per second, nominal
    • DC voltage measurement:
      • Range: 400.0mV, 4.000V, 40.00V, 400.0V, 1000V
      • Basic accuracy: +/- (1.2%+2d)
      • Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
    • AC voltage measurement:
      • Range: 400.0mV, 4.000V, 40.00V, 400.0V, 750V
      • Basic accuracy: +/- (0.8%+3d)
      • Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
    • DC current measurement:
      • Range: 400.0uA, 4000uA, 40.00mA, 400.0mA, 20A
      • Basic accuracy: +/- (1.5%+3d)
      • Resolution: 0.1uA, 1uA, 10uA, 100uA, 10mA
    • AC current measurement:
      • Range: 400.0uA, 4000uA, 40.00mA, 400.0mA, 20A
      • Basic accuracy: +/- (1.8%+5d)
      • Resolution: 0.1uA, 1uA, 10uA, 100uA, 10mA
    • Resistance measurement (Ohm):
      • Range: 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00MW
      • Basic accuracy: +/- (1.0%+2d)
      • Resolution: 0.1, 1, 10, 100, 1k, 10k
    • Frequency measurement:
      • Range: 9.999Hz, 99.99Hz, 999.9Hz, 9.999kHz, 99.99kHz, 999.9kHz,9.999MHz
      • Basic accuracy: +/- (1.2%+3d)
      • Resolution: 0.001Hz, 0.01Hz, 0.1Hz, 1Hz, 10Hz, 100Hz, 1kHz
    • Capacitance measurement:
      • Range: 40.00nF, 400.0nF, 4.000uF, 40.00uF, 100.0uF
      • Basic accuracy: +/- (3.5%+5d)
      • Resolution: 10pF, 0.1nF, 1nF, 10nF, 0.1uF
    • Duty cycle measurement:
      • Range: 0.1%-99.9%
      • Basic accuracy: +/- (1.2%+2d)
      • Resolution: 0.1%
    • Temperature measurement:
      • Range: -20~+1000/ -4 ~+1832
      • Basic accuracy:+/- (3%+2 / )
      • Resolution: 0.1 /
    • Diode check and continuity test:
      • Diode test: test current of 0.3mA maximum, open circuit voltage1.5V DC typical
      • Audible continuity check: audible signal will sound if theresistance is less than 30Ohm (approx.), test current<0.3mA
  • Oversized high contrast 4000 counts backlight LCD display withdual display
  • Safety warning LCD-annunciator
  • Auto ranging
  • Data hold, auto power off and low battery indication
  • Measurement rate: 2 times per second, nominal
  • DC voltage measurement:
    • Range: 400.0mV, 4.000V, 40.00V, 400.0V, 1000V
    • Basic accuracy: +/- (1.2%+2d)
    • Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
  • AC voltage measurement:
    • Range: 400.0mV, 4.000V, 40.00V, 400.0V, 750V
    • Basic accuracy: +/- (0.8%+3d)
    • Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
  • DC current measurement:
    • Range: 400.0uA, 4000uA, 40.00mA, 400.0mA, 20A
    • Basic accuracy: +/- (1.5%+3d)
    • Resolution: 0.1uA, 1uA, 10uA, 100uA, 10mA
  • AC current measurement:
    • Range: 400.0uA, 4000uA, 40.00mA, 400.0mA, 20A
    • Basic accuracy: +/- (1.8%+5d)
    • Resolution: 0.1uA, 1uA, 10uA, 100uA, 10mA
  • Resistance measurement (Ohm):
    • Range: 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00MW
    • Basic accuracy: +/- (1.0%+2d)
    • Resolution: 0.1, 1, 10, 100, 1k, 10k
  • Frequency measurement:
    • Range: 9.999Hz, 99.99Hz, 999.9Hz, 9.999kHz, 99.99kHz, 999.9kHz,9.999MHz
    • Basic accuracy: +/- (1.2%+3d)
    • Resolution: 0.001Hz, 0.01Hz, 0.1Hz, 1Hz, 10Hz, 100Hz, 1kHz
  • Capacitance measurement:
    • Range: 40.00nF, 400.0nF, 4.000uF, 40.00uF, 100.0uF
    • Basic accuracy: +/- (3.5%+5d)
    • Resolution: 10pF, 0.1nF, 1nF, 10nF, 0.1uF
  • Duty cycle measurement:
    • Range: 0.1%-99.9%
    • Basic accuracy: +/- (1.2%+2d)
    • Resolution: 0.1%
  • Temperature measurement:
    • Range: -20~+1000/ -4 ~+1832
    • Basic accuracy:+/- (3%+2 / )
    • Resolution: 0.1 /
  • Diode check and continuity test:
    • Diode test: test current of 0.3mA maximum, open circuit voltage1.5V DC typical
    • Audible continuity check: audible signal will sound if theresistance is less than 30Ohm (approx.), test current<0.3mA
  • Range: 400.0mV, 4.000V, 40.00V, 400.0V, 1000V
  • Basic accuracy: +/- (1.2%+2d)
  • Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
  • Range: 400.0mV, 4.000V, 40.00V, 400.0V, 750V
  • Basic accuracy: +/- (0.8%+3d)
  • Resolution: 0.1mV, 1mV, 10mV, 100mV, 1V
  • Range: 400.0uA, 4000uA, 40.00mA, 400.0mA, 20A
  • Basic accuracy: +/- (1.5%+3d)
  • Resolution: 0.1uA, 1uA, 10uA, 100uA, 10mA
  • Range: 400.0uA, 4000uA, 40.00mA, 400.0mA, 20A
  • Basic accuracy: +/- (1.8%+5d)
  • Resolution: 0.1uA, 1uA, 10uA, 100uA, 10mA
  • Range: 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00MW
  • Basic accuracy: +/- (1.0%+2d)
  • Resolution: 0.1, 1, 10, 100, 1k, 10k
  • Range: 9.999Hz, 99.99Hz, 999.9Hz, 9.999kHz, 99.99kHz, 999.9kHz,9.999MHz
  • Basic accuracy: +/- (1.2%+3d)
  • Resolution: 0.001Hz, 0.01Hz, 0.1Hz, 1Hz, 10Hz, 100Hz, 1kHz
  • Range: 40.00nF, 400.0nF, 4.000uF, 40.00uF, 100.0uF
  • Basic accuracy: +/- (3.5%+5d)
  • Resolution: 10pF, 0.1nF, 1nF, 10nF, 0.1uF
  • Range: 0.1%-99.9%
  • Basic accuracy: +/- (1.2%+2d)
  • Resolution: 0.1%
  • Range: -20~+1000/ -4 ~+1832
  • Basic accuracy:+/- (3%+2 / )
  • Resolution: 0.1 /
  • Diode test: test current of 0.3mA maximum, open circuit voltage1.5V DC typical
  • Audible continuity check: audible signal will sound if theresistance is less than 30Ohm (approx.), test current<0.3mA