  • AT-9955 automotive DMM with IR laser thermometer providesmultiple functions, can be used for many different diagnostic workson car and truck
  • Specifications:
    • DCV range: 400mV, 4V, 40V, 400V, 1000V; accuracy:+/-(0.5%+2d)
    • ACV range: 400mV, 4V, 40V, 400V, 700V; accuracy:+/-(0.8%+4d)
    • DCA range: 400uA, 4000uA, 40mA, 400mA, 4A, 20A; accuracy:+/-(1.2%+2d)
    • ACA range: 400uA, 4000uA, 40mA, 400mA, 4A, 20A; accuracy:+/-(1.5%+4d)
    • Resistance range: 400 ohm, 4k ohm, 40k ohm, 400k ohm, 4M ohm,40M ohm; accuracy: +/-(0.8%+3d)
    • RPM (tach) range: 600 - 4,000rpm, 600 - 12,000rpm (x10rpm);accuracy: +/-(2.0%+2d)
    • Dwell angle: 4, 5, 6, 8 CYL; accuracy: +/-(2.5%+2d)
    • Duty cycle: 0.1 - 99.9%; accuracy: +/-(1.5%+2d)
    • Frequency range: 0.001Hz - 9.99MHz; accuracy: +/-(2.0%+2d)
    • Temperature range: -20 - 76°C (-4 - 140°F); accuracy:+/-(3.0%+2d)
    • IR temperature: -20 - 28°C (-4 - 536°F); accuracy:+/-(3.0%+2d)
    • Capacitance range: 40nF, 400nF, 4uF, 40uF, 400uF, 4mF, 40mF;accuracy: +/-(3.0%+2d)
    • Pulse width: 0.1 - 10mS; accuracy: +/-(3.0%+5d)
    • Diode check: open circuit voltage 3V DC
    • Test current: 0.3mA typical
    • Continuity test: threshold 30 ohm, continuity beeper 2kHz
    • Dimensions: 182 x 82 x 55mm
    • Weight: approximate 360g
  • DCV range: 400mV, 4V, 40V, 400V, 1000V; accuracy:+/-(0.5%+2d)
  • ACV range: 400mV, 4V, 40V, 400V, 700V; accuracy:+/-(0.8%+4d)
  • DCA range: 400uA, 4000uA, 40mA, 400mA, 4A, 20A; accuracy:+/-(1.2%+2d)
  • ACA range: 400uA, 4000uA, 40mA, 400mA, 4A, 20A; accuracy:+/-(1.5%+4d)
  • Resistance range: 400 ohm, 4k ohm, 40k ohm, 400k ohm, 4M ohm,40M ohm; accuracy: +/-(0.8%+3d)
  • RPM (tach) range: 600 - 4,000rpm, 600 - 12,000rpm (x10rpm);accuracy: +/-(2.0%+2d)
  • Dwell angle: 4, 5, 6, 8 CYL; accuracy: +/-(2.5%+2d)
  • Duty cycle: 0.1 - 99.9%; accuracy: +/-(1.5%+2d)
  • Frequency range: 0.001Hz - 9.99MHz; accuracy: +/-(2.0%+2d)
  • Temperature range: -20 - 76°C (-4 - 140°F); accuracy:+/-(3.0%+2d)
  • IR temperature: -20 - 28°C (-4 - 536°F); accuracy:+/-(3.0%+2d)
  • Capacitance range: 40nF, 400nF, 4uF, 40uF, 400uF, 4mF, 40mF;accuracy: +/-(3.0%+2d)
  • Pulse width: 0.1 - 10mS; accuracy: +/-(3.0%+5d)
  • Diode check: open circuit voltage 3V DC
  • Test current: 0.3mA typical
  • Continuity test: threshold 30 ohm, continuity beeper 2kHz
  • Dimensions: 182 x 82 x 55mm
  • Weight: approximate 360g