
OLED Display Finger Pulse Oximeter SpO2 Monitor
- Payment Type:
- L/C, T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Product Description
OLED Display Finger Pulse Oximeter SpO2 Monitor - CE&FDA ApprovedMajor Features1. Integrated with SpO2 probe and processing display module2. Small in volume\light in weight and convenient in carrying3. Operation of the product is simple, low power consumption4. Operation menu for the function setting5. SpO2 value display6. Pulse rate value display, bar graph display7. Pulse waveform display8. The display mode can be changed9. Screen brightness can be changed10. A pulse rate sound indication11. With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable12. Battery capacity indication13. Low-voltage indication: Low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function14. With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers15. Real-time data can be transmitted to computers16. Automatically power off function: When the device is under the state of measuring interface. It will automatically power off within 5 seconds if the finger falls out of probe17. Wireless communication(CMS50EW)18. RF Wireless communication function(Option)(Only applied for Ver6.6R or above)19. Connected with an external oximeter probe(Option)(CMS50EW, only applied for Ver6.6R or above of CMS50E)Main performanceDisplay Mode: 1.3" 65K Color OLED displayScreen Resolution: 128*96SpO2 Measuring Range: 0%~100%, (the resolution is 1%). Accuracy: 70%~100%: ± 2%, Below 70% unspecified. PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)Accuracy: ± 2bpm or ± 2% (select larger)Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger). Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%. Power Consumption: Less than 100mAVoltage: DC 3.6V~4.2VPower Supply: Voltage 3.7 rechargeable lithium battery × 1Battery Working Hour: 20 hoursBattery working life: Charge and discharge no less than 500 times. Safety Type: Interior Battery, BF TypeSell in addition: 1. Oximeter probe(Refer to probe application instruction for details and notice renewal)2. RF wireless module(Only applied for Ver6.6R or above of CMS50E)Physical IdentityDimension: 57(L) × 32(W) × 30 (H) mmWeight: About 50g (with the lithium battery*1)Certificates: FDA CEDisplay Mode1.3" 65K Color OLED DisplayScreen Resolution128*96Display ContentSPO2 Value, PR Value, WaveformSpO2 Measuring Range0%~100%, (the resolution is 1%). Accuracy70%~100%: ± 2%, Below 70% unspecified. PR Measuring Range30bpm~250bpm, (the resolution is 1bpm)Accuracy± 2bpm or ± 2% (select larger)Measurement Performance in Weak Filling ConditionSpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger). Resistance to Surrounding LightThe deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%. Power Consumptionless than 100mAVoltageDC 3.6V~4.2VPower SupplyVoltage 3.7 rechargeable lithium battery × 1Battery Working Hour20 hoursBattery Working LifeCharge and discharge no less than 500 times. Safety TypeInterior Battery, BF TypeDimension57(L) × 32(W) × 30 (H) mmWeightAbout 50g (with the lithium battery*1)CertificateCE, FDASell in StandardA hanging ropeA user manualA data lineA disk (PC software)A power adapter
Related Keywords
Related Keywords