
Multi Parameter Patient Monitor (15 Inch, MT-8000G)
- Payment Type:
- L/C, T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Product Description
Multi Parameter Patient Monitor (15 Inch, MT-8000G)Standard configuration15 inch TFT; Resolution: 1024*768ECG, SpO2, PR, NIBP, RESP, TEMPFunction: Standard configuration ( Include ECG, RESP, TEMP, PR, SpO2, NIBP ), Built-in Lead-acid battery, one more battery, thermal recorder, touch screen, IBP, ETCO2, fetal monitor and Anesthetic depth can be optional. High light LED double tubes design, adopt Japanese good air tightness and low noise air pump, and the cable are both medical environmental materials, complete function, 15 inch display and unique Anesthetic depth monitoring make it can be widely used on the surgery and diagnosis. Characteristics1. Patent: Unique two modulator tube design, the display can work even one of that can not be used, this insure the display long-life usage2. Safe: Adopt PU/TPU environmental cable and ensure the users' safety3. Display: Import the Japanese SHARP TFT LCD display and ensure the high-light effect and no light-spot and waviness4. Battery: One more battery can be optional, battery jar has good resilience and tightness. 5. Gold-plating probe terminal: Solid and durable, especially ensure the users' safety6. High quality components and parts: Import Japanese air pump, good air tightness and low noise, American SMI pressure sensors make the measurement result more accurate. 7. Working environment: Wide range of temperature and humidity8. Operate: Single key operating main function make the monitor easy9. Optional ParametersThermal Recorder, Lead-acid Battery, IBP, ETCO2, Monitor depth of anesthesia, Anesthesia, gas monitoring, Oxygen monitoring#ECGLeads Mode; 5 leads; I\II\III\AVR\Avl\Avf\VGain(mm/mV): 1/4, 1/2, 1, 2, 4Scanning speed; 12.5mm/s\25mm/s\50mm/sFrequency response: Diagnosis 0.05-130HzMonitoring 0.5 - 40HzOperation 1.0- 20HzHeart rate range: 15-350 BPMHeart rate accuracy: ± 1%ST segment analysis: -0.8- 0.8MvST segment accuracy: ± 0.02Mv#NIBPMeasure and Alarm RangeAdult ModeSYS 40 ~ 280 mmHgDIA 10 ~ 220 mmHgMEAN 20 ~ 240 mmHgPediatric ModeSYS 40 ~ 220 mmHgDIA 10 ~ 160 mmHgMEAN 20 ~ 170 mmHgNeonatal ModeSYS 40 ~ 135 mmHgDIA 10 ~ 100 mmHgMEAN 20 ~ 110 mmHgStatic pressure range: 0~300mmHgStatic pressure accuracy: ± 3mmHg or 2%Resolution: 1mmHgProtection mode; Dual over voltage protection#SpO2Measure range: 1-100%Accuracy: ± 2% (70-100%)Resolution: 1%#Pulse rateMeasure range: 20-300 BPMAccuracy: ± 2 BPMResolution: 1 BPM#TemperatureChannel; 2Measure range: 0-50 centidegreeAccuracy: ± 0.1 centidegreeResolution: 0.1 centidegree#RespirationMeasure range; Adult 0~120BrPMPediatric/ Neonatal 0~150BrPMAccuracy: ± 2%Resolution: 1 BPM#IBP(optional)Accuracy (no sensor); ± 2%or1mmHgBand width: Normal mode: DC~40HzSmooth mode: DC~12.5Hz#ETCO2Measure range: 0% - 13%Resolution: 1 mmHgAccuracy: ± 2 mmHg @ < 5.0% CO2 (at ATPS)Respiration: 3 - 150 bpm#Depth of anesthesia (optional)EEG sensitivity ± 400μ VNoise < 2μ Vp-p, < 0.4μ V RMS, 1-250HzCMRR >100dBInput impedance >50MohmSample rate 2000 samples/sec. (14 bits equivalent)CSI and update 0-100. Filter 6-42Hz, 1 sec. UpdateEMG 0-100logarithmic. Filter75-85Hz, 1sec. UpdateBS% 0-100%. Filter 2-42 Hz, 1 sec. Update#OptionLead-acid battery (extermal plug)Recorder (built-in)IBPETCO2Monitor depth of anesthesiaAnesthesia gas monitoringOxygen monitoring
Related Keywords
Related Keywords