Shenzhen First Mile Communications Ltd.
Shenzhen First Mile Communications Ltd.
Gigabit Managed Industrial Ethernet Switch IDS 509/510
  • Gigabit Managed Industrial Ethernet Switch IDS 509/510
Gigabit Managed Industrial Ethernet Switch IDS 509/510

Gigabit Managed Industrial Ethernet Switch IDS 509/510

Payment Type:
L/C, T/T
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen
Payment Type: L/C, T/T
Product Description
Product Description
IDS 509/510 Entry Level Series

Standards:
IEEE 802.3
IEEE 802.3u
IEEE 802.3ab
IEEE 802.1D-2004 for STP
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3x for Flow Control
Protocols:
IGMPv1/v2, GVRP, SNMPv1/v2c/v3, DHCP Client,
TFTP, SMTP, RMON, HTTP, HTTPS, Telnet, Syslog,
SSH, SNMP Inform, LLDP, SNTP Server/Client
MIB:
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB,
Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control:
IEEE 802.3x flow control, back pressure flow control
Switch Properties:
Priority Queues: 4
Max. Number of Available VLANs: 256
VLAN ID Range: VID 1 to 4094
IGMP Groups: 256
MAC Table Size: 8K
Packet Buffer Size: 1 Mbit
Interface:
Fiber Ports: 1000BaseX (SFP slots)
RJ45 Ports: 10/100BaseTX or 10/100/1000BaseTX auto negotiation
Console Port: RS-232(RJ45 connector)
Alarm Contact: 2 relay outputs with current carrying capacity of 1A@24V
Power Requirements:
Input Voltage: 24 VDC (18 to 36VDC), redundant dual inputs
Input Current: 0.24A@24VDC
Overload Current Protection: Present
Reverse Polarity Protection: Present
Connector: 6-contact terminal blocks
Operating Temperature:
Standard Models: 0 to +60° C (32 ~ 140° F )
Wide Temp. Models: -40 to +75° C (-40 to 167° F)
Storage Temperature: -40 to +85° C (-40 to 185° F )
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications:
Safety: UL 60950-1
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8 Level 3
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Warranty Period: 5years