Combustible Gas Detector (SPD202)
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | T/T |
Product Description
Product Description
Features:
SPD202 combustible gas detector can be used in hazardous areas indoors and outdoors, where combustible gas is produced, stored, used, etc., such as chemical, petroleum, metallurgy, oil depot, LPG (Liquefied Petroleum Gas) station, pharmaceutical, gas transmission and distribution, etc. To detect the leakage and show the leaking concentration with a digital display. This device can set two-level alarming value. The detector can raise the acousto-optic alarming when the detected concentration reaches the preset value
Technical specification:
1) Detecting principle: Catalytic combustion
2) Detected gas: Combustible gas
3) Measurement range: 0-100% LEL (LEL: Low Explosion Level - the lowermost concentration of combustible gas to generate an explosion in air when meeting a naked flame)
4) Resolution: 0.1%
5) Error: ± 2%
6) Response time: <30s
7) Operation temperature: -10~60
8) Operation humidity: <99%RH
9) Display mode: Digital display with large LCD screen
10) Alarming method: Acousto-optic alarming
11) Power supply: 4× 1.5V AA batteries
12) Current:
<110mA (measuring status)
<15mA (non-measuring status)
SPD202 combustible gas detector can be used in hazardous areas indoors and outdoors, where combustible gas is produced, stored, used, etc., such as chemical, petroleum, metallurgy, oil depot, LPG (Liquefied Petroleum Gas) station, pharmaceutical, gas transmission and distribution, etc. To detect the leakage and show the leaking concentration with a digital display. This device can set two-level alarming value. The detector can raise the acousto-optic alarming when the detected concentration reaches the preset value
Technical specification:
1) Detecting principle: Catalytic combustion
2) Detected gas: Combustible gas
3) Measurement range: 0-100% LEL (LEL: Low Explosion Level - the lowermost concentration of combustible gas to generate an explosion in air when meeting a naked flame)
4) Resolution: 0.1%
5) Error: ± 2%
6) Response time: <30s
7) Operation temperature: -10~60
8) Operation humidity: <99%RH
9) Display mode: Digital display with large LCD screen
10) Alarming method: Acousto-optic alarming
11) Power supply: 4× 1.5V AA batteries
12) Current:
<110mA (measuring status)
<15mA (non-measuring status)