Chd805t Single Door Double- Way Access Controller
- Payment Type:
- T/T, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen |
---|---|
Payment Type: | T/T, Western Union |
Product Description
Product Description
Dimension: 356mm(L)×265mm(W)×62mmH)±5%
Net weight: 2.8Kg±5%
Color: Black
Rated operational voltage: AC220V 50Hz
Output voltage range: AC100-240V
Working current: The controller maximum working current less than 300mA
Minimum supply current: 2A/AC220V input
Authorization user: 1700(The number can expand to 10576)
Event record: 6144
Communication mode: Standard RS485, YDB023-1996; (RS422 communication interface should be ordered in advance)
Communicate rate: 9600BPS
Card reader interface: 2 units wiegand input interface, can external connect 2 units wiegand card-readers, can distinguish entry and exit. Support password keypad card reader.
Input interface: 4groups Optical coupling isolation input(exit button, door switch, infrared, emergency linkage)
Output interface: One door-open relay, one alarm output relay
Drive capability: Relay output MAX: DC12V/2A/25SEC 24V/25SEC AC75V/3A/25SEC
Working status: Sound and light prompt. Power on indicator light, read card open the door and other actions buzzer voice prompt.

Net weight: 2.8Kg±5%
Color: Black
Rated operational voltage: AC220V 50Hz
Output voltage range: AC100-240V
Working current: The controller maximum working current less than 300mA
Minimum supply current: 2A/AC220V input
Authorization user: 1700(The number can expand to 10576)
Event record: 6144
Communication mode: Standard RS485, YDB023-1996; (RS422 communication interface should be ordered in advance)
Communicate rate: 9600BPS
Card reader interface: 2 units wiegand input interface, can external connect 2 units wiegand card-readers, can distinguish entry and exit. Support password keypad card reader.
Input interface: 4groups Optical coupling isolation input(exit button, door switch, infrared, emergency linkage)
Output interface: One door-open relay, one alarm output relay
Drive capability: Relay output MAX: DC12V/2A/25SEC 24V/25SEC AC75V/3A/25SEC
Working status: Sound and light prompt. Power on indicator light, read card open the door and other actions buzzer voice prompt.

Related Keywords