
Smoke/Fire Detector/Sensors for Alarm Systems (TA-2988)
- Payment Type:
- T/T, Paypal, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | T/T, Paypal, Western Union |
Product Description
Product Description
Product Description
Alarm Smoke Detector TA-2988
For more details, please:
Contact: Tina
Sype: Dana_z88
TEL: 0086 -13316516142
Introduction
TA-2988 series optical smoke detectors are designed to respond to a wide spectrum of fires and ease installation. Every unit is individually tested and calibrated to ensure high reliability and prevent false alarms
Advanced photoelectric smoke sensing technology
Durable sensor head; Excellent smoke access
Ar (auto reset) function for security systems(optional for 4 wire models)
N/c (normal/close)-n/o (normal/open) selectable relay output
Easy installation and maintenance
Modern design (white and beige colors)
Freq.: 3~5 sec
Sensor base: Standard and shottky diode
Remote led
Comply with en54 and ce
Smoke sensitivity: EN 54-5/7: 2000 standard
Detection range: 100 square meters rating for smoke sensor; 50 square meters rating for heat sensor
Start-up current: 70 μ A maximum
Alarm impedance: For 2-wire models: 100Ω +3v max; 560Ω +3v max (red led open circuit)
Alarm indicator: Led continuously emitting red light
Temperature range: -10 ° C to 50 ° C
Remote output: 15 ma max, diode gate
Humidity: 0 to 95% rh, noncondensing
Alarm contact: For 4-wire: N/o or n/c operation
Form a: 1.0a@30vdc/0.5a@125vac
Dimensions: 10mm (dia) x 46mm (ht) with base
Weight: 130g/set with base
For more details, please:
Contact: Tina
Sype: Dana_z88
TEL: 0086 -13316516142
Introduction
TA-2988 series optical smoke detectors are designed to respond to a wide spectrum of fires and ease installation. Every unit is individually tested and calibrated to ensure high reliability and prevent false alarms
Advanced photoelectric smoke sensing technology
Durable sensor head; Excellent smoke access
Ar (auto reset) function for security systems(optional for 4 wire models)
N/c (normal/close)-n/o (normal/open) selectable relay output
Easy installation and maintenance
Modern design (white and beige colors)
Freq.: 3~5 sec
Sensor base: Standard and shottky diode
Remote led
Comply with en54 and ce
Smoke sensitivity: EN 54-5/7: 2000 standard
Detection range: 100 square meters rating for smoke sensor; 50 square meters rating for heat sensor
Start-up current: 70 μ A maximum
Alarm impedance: For 2-wire models: 100Ω +3v max; 560Ω +3v max (red led open circuit)
Alarm indicator: Led continuously emitting red light
Temperature range: -10 ° C to 50 ° C
Remote output: 15 ma max, diode gate
Humidity: 0 to 95% rh, noncondensing
Alarm contact: For 4-wire: N/o or n/c operation
Form a: 1.0a@30vdc/0.5a@125vac
Dimensions: 10mm (dia) x 46mm (ht) with base
Weight: 130g/set with base
specification: | |
Name: | smoke/fire detector/sensors(TA-2988) |
Model: | PARADOX 643LCD |
operating voltage: | DC 12V-24V |
Monitoring current: | ≤50μA |
Alarm current: | ≤20mA |
Freq | 3~5 sec |
smoke sensitivity: | EN 54-5/7:2000 standard |
alarm contact: | for 4-wire: n/o or n/c operation |
detection range: | 100 square meters rating for smoke sensor; 50 square meters rating for heat sensor |
humidity: | 0 to 95% rh, noncondensing |
dimensions: | 10mm (dia) x 46mm (ht) with base |
temperature range: | -10to 50centigrade |
remote output: | 15 ma max, diode gate |
weight: | 130g/set with base |
Operating environment: | temperature"-10-+50 centigrade |
relative humidity:≤95%(40±2centigrade) | |
connection method: | Two-wire and non-polarity system |
suitable situations: | Hotel,apartment, office,machinery room and entertainment places |
The places having risk of the electric fire. | |
None-suitable situations: | The places where smoke detained is usual |
The places where black smoke may be produced in the fire. | |
The places there are the dust,fop,steam,oily fog and other decay gas |
Related Keywords
Related Keywords
You May Also Like
You May Also Like