Shenzhen Taian Electronics Co., Ltd.
Shenzhen Taian Electronics Co., Ltd.
Paradox 18-Zone Alarm Host (PA-738ULT/646)
  • Paradox 18-Zone Alarm Host (PA-738ULT/646)
Paradox 18-Zone Alarm Host (PA-738ULT/646)

Paradox 18-Zone Alarm Host (PA-738ULT/646)

Payment Type:
T/T, Paypal, Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Payment Type: T/T, Paypal, Western Union
Product Description
Product Description

Product Description

8 zone inputs (16 zones with zone doubling) + 2 keypad zones
1.1A switching power supply
CTR-21 approved dialer
2 partitions
49 user codes
256 events buffered
2 PGM outputs + 1 alarm relay
Supervised bell output, auxiliary output and telephone line
2-wire smoke detector input option (input 3)
Serial or parallel wiring for zone doubling connections
Master Code Lock: Cannot change or delete the Master Code or User Code 01
Supports pager reporting
Closing Delinquency Timer: Transmit a report when last arming exceeds timer
Auto-test report can now be set in hours or days
Timed Test Transmission feature
Includes 28cm X 28cm X 8cm (11" X 11" X 3") metal box
Zone recognition
Device connected to which input? 728+  728+ 738+ 738+
No ATZ With ATZ No ATZ With ATZ
Control panel        
Input 1= Zone 1 Zone 1&2 Zone 1 Zone 1&9
Input 2= Zone 2 Zone 3&4 Zone 2 Zone 2&10
Input 3= Zone 3 Zone 5&6 Zone 3 Zone 3&11
Input 4= Zone 4 Zone 7&8 Zone 4 Zone 4&12
Input 5= N/A N/A Zone 5 Zone 5&13
Input 6= N/A N/A Zone 6 Zone 6&14
Input 7= N/A N/A Zone 7 Zone 7&15
Input 8= N/A N/A Zone 8 Zone 8&16
Keypad        
Zone 1= Zone 5 Zone 9 Zone 9 Zone 17
Zone 2= Zone 6 Zone 10 Zone 10 Zone 18