Vertical Fan Coil Unit
  • Vertical Fan Coil Unit
Vertical Fan Coil Unit

Vertical Fan Coil Unit

Payment Type:
L/C, T/T, Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Guangdong
Payment Type: L/C, T/T, Western Union
Product Description
Product Description
Vertical Fan Coil Unit
1, Exquisite Structure, pleasing in appearance, reasonable product structure, fire insulation.
2, It has the fine design, light weight and good strength, also easy installation.
3, The effiency is high. Fan coil adopt seamless red Copper Pipe and aluminum blinds-fin. Mechanical expand tubes make sure the Close contact between fin and cooper pipe, reaching he best heat transfer. Before leaving factory strict test is done, so is the 100% pressure leak testing (20 kg/cm2 pressure leak test), to ensure product quality and performance.
4, It is easy to control and owns complete functions.
5. Ceiling Exposed, Ceiling Concealed, Floor Mounted, Cassette type for optional.

Specifications

Water Chilled Fan Coil Units, Concealed fan coil for duct installation both exposed version and concealed version available, LCD controller hydraulic fan coil
Air Flow: 340m3/h--2380m3/h.
Water chilled Fan Coil Units
Cooling capacity: 1.8kw--12.6kw
Model: HLC-34-238VE
Power supply: 220V/1PH/50HZ and 110V/1PH/60HZ
Characters
The HLC series water chilled fan coil units are designed specially to meet the varied requirements of zone cooling or heating using chilled water or hot water.
This unit is presented as a single block including: Fan deck, cooling and/or cooling coil, removable filter, drip tray, electrical connection box and decorative cabinet (excluded for concealed version).

OPTIONAL
L Condensation tray (water connection area)
L Different type thermostats with more advanced functions
Application:
Fan coil units is the indoor terminal units of the air conditioning system, . Applicable to hotels, villas, hospitals, cinemas, stadiums, recreations, office blocks, factories and so on.
Note:
1. The noise value is tested in all the mute indoor, under norm operation condition, the measuring point is 1 meter away in front of the unit and 1 meter below the unit.
2. Cooling capacity is tested under: Air inlet DB=27° C, WB=19.5° C, intake water temperature=7° C, outlet water temperature=5° C, and 3 column coil.
3. Heating capacity is tested under: Air inlet DB=21° C, intake water temperature 60° C, same water flow condition as testing cooling capacity, and 3 column coil.