Shenzhen ZLPOWER Electronics Co., Ltd.
Shenzhen ZLPOWER Electronics Co., Ltd.
LED UPS-Small UPS-Offline UPS-Standby Offline UPS-Line Interractive UPS 400va-1500va
  • LED UPS-Small UPS-Offline UPS-Standby Offline UPS-Line Interractive UPS 400va-1500va
LED UPS-Small UPS-Offline UPS-Standby Offline UPS-Line Interractive UPS 400va-1500va

LED UPS-Small UPS-Offline UPS-Standby Offline UPS-Line Interractive UPS 400va-1500va

Payment Type:
L/C, T/T, Western Union, Money Gram
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Payment Type: L/C, T/T, Western Union, Money Gram
Product Description
Product Description
LED UPS-Small UPS-Offline UPS-Standby Offline UPS-Line Interractive UPS 400VA-1500VA
Product Features

IP/OP: 110/220VAC 50/60Hz
IP/OP: 110/220VAC 50/60Hz

KEY FEATURES
Optional function
Line Surge Protection: RJ11/RJ12/RJ45, Communication Interface: RS232
Function & Characteristic:
AVR, Overload and short circuit protection
Low battery alarm, LED status display
UPS Auto on when AC back, Night charging(optional)
APPLICATION
Home, computer, printer, POS, Comouter Peripherals

Product performance

TECHNICAL SPECIFICATION
MODEL N400 N500 N650 N800 N1000 N1200 N1500
Nominal Capacity 400VA/240W 500VA/300W 650VA/390W 800VA/480W 1000VA/600W 1200VA/720W 1500VA/900W
Input Voltage Range 145~280VAC/ 80VAC-150VAC
Frequency 50/60Hz
Output Voltage Range 220VAC/120VAC ± 10%
Frequency 50Hz/60Hz ± 5%
Output Waveform Square Wave
Transfer time < 10ms
Battery Type Sealed free maintenance lead acid battery
Capacity 12V, 4AH *1PCS 12V, 7AH *1PCS 12V, 7AH *1PCS 12V, 9AH *1PCS 12V, 7AH *2PCS 12V, 9AH *2PCS 12V, 9AH *2PCS
Recharge Time 8 hrs to 90% of capacity full load discharge
Protection Auto protect
Back-up time( Full load ) 3~5 min 5~7 min 7~10 min 6~8 min 5~7 min 8~10 min 10-12min
Function Auto voltage output on AC mode, Auto shutoff if short circuit or overload
dB-9 port, communication software Optional RS232, RJ11, RJ45, USB
Protection AC mode Fuse
Short circuit AC Fuse
Invert mode Auto protect
Alarm Alarm Battery discharge Alarm beeps every four seconds
Low battery voltage Alarm beeps every second
Overload Alarm beeps continuously
Indicator light Auto adjust Green lighting: AC mode
Battery Discharge Red lighting: Battery mode
Environment Operating temperature 0C~40C
Operating Humidity 0-90% non-condensing
Noise <35dB(1 meter distance)
UPS Dimension(L× W× H)mm 325*90*150 335*100*150 345*125*190
Net weight (N. W) 4.5KG 6.5KG 6.8KG 7.5KG 11KG 12KG 13KG
Gross weight (G. W) 4.7KG 6.7KG 7KG 7.7KG 11.3KG 12.3KG 13.3KG