New Charpy Testing Machine (PIT452G)
- Payment Type:
- L/C, T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Product Description
Description
WANCE offers PIT452G pendulum impact testing machine designed for determining the impact resistance of metallic materials under dynamic loading.
This series is engineered for maximum accuracy, simplicity of design, ease of operation and safety, and performs standard notched bar impact tests.
Equipped with force transducer, precise data sampling and measurement system, it fully satisfies instrumented impact tests complying with international standards.
Standards
ASTM E23, ASTM E1820, ASTM E2298, ISO 148, EN10045,
GB/T 3808, GB/T 229, JJG145, JJG 609
Significance and use
Compared with traditional pendulum impact testing machine, instrumented type is more useful for accurate analysis of material property during crack, facilitating the engineers to understand the most fragile part of materials when developing new materials.
In addition to providing an measure of total absorbed energy (Wt), instrumented testing enables the determination of characteristic force, energy, and displacement parameters, such as the pre-maximum force energy (Wm); the post maximum force energy; the general yield force (Fgy); the force at brittle fracture initiation (Fbf); the arrest force (Fa).
Wance is the leading R&D and manufacturing of instrumented impact testing system in China, and has experienced experts for force transducer design. Combined with our high speed data sampling system, Wance provides the full complement of solutions for laboratory, ranging from 0.1J for engineering plastic to 100,000J for steel DWTT test.
Machine structure
The basic model consists of a heavy steel base on which the specimen holder (anvil) and a heavy-duty cast steel upright are mounted.
Pendulum & Anvil/Vice
High stiffness pendulum rod ensures no vibration after impact.
Changing counter weight is simple to change pendulum capacity, switching between 450J and 300J.
Customer can change striking knife according to test standard requirements, such as R2 for ISO/GB standard, R8 for ASTM, or R2/R8 instrumented knife, or Izod knife complying with ASTM E23.
Specimen holders have a few options, such as Charpy anvil, Izod vice, Brugger test fixture and wedge test fixture.
Pendulum lock & release system
It features damping design during pendulum locking to prevent any damages, lower noises and improve durability and safety.
Driving system:
This series adapts standard double speed reducer instead of old complicated driving system, featuring simple structure, easy repair, and high durability and free of maintenance.
Angle measurement system
Japanese made NEMICON high precision optical encoder is used for angle measurement, angle resolution can reach 0.025° to ensure high accuracy of impact energy.
Safety system:
This series of machine has fully closed protection shield to protect operator against specimen splitting during test, and to deny any access to the inside during test. Built-in door interlock further ensures operator safety. The protection shield is constructed with aluminum alloy profile for frame and fiber glass for easy observation. Split-type door design is simple to repair and change pendulum.
Energy display system
Three types of energy display are available:
Ø Dial gauge: simple and direct to read impact energy
Ø Wide view touch screen
Ø Computer with test software
WANCE offers PIT452G pendulum impact testing machine designed for determining the impact resistance of metallic materials under dynamic loading.
This series is engineered for maximum accuracy, simplicity of design, ease of operation and safety, and performs standard notched bar impact tests.
Equipped with force transducer, precise data sampling and measurement system, it fully satisfies instrumented impact tests complying with international standards.
Standards
ASTM E23, ASTM E1820, ASTM E2298, ISO 148, EN10045,
GB/T 3808, GB/T 229, JJG145, JJG 609
Significance and use
Compared with traditional pendulum impact testing machine, instrumented type is more useful for accurate analysis of material property during crack, facilitating the engineers to understand the most fragile part of materials when developing new materials.
In addition to providing an measure of total absorbed energy (Wt), instrumented testing enables the determination of characteristic force, energy, and displacement parameters, such as the pre-maximum force energy (Wm); the post maximum force energy; the general yield force (Fgy); the force at brittle fracture initiation (Fbf); the arrest force (Fa).
Wance is the leading R&D and manufacturing of instrumented impact testing system in China, and has experienced experts for force transducer design. Combined with our high speed data sampling system, Wance provides the full complement of solutions for laboratory, ranging from 0.1J for engineering plastic to 100,000J for steel DWTT test.
Machine structure
The basic model consists of a heavy steel base on which the specimen holder (anvil) and a heavy-duty cast steel upright are mounted.
Pendulum & Anvil/Vice
High stiffness pendulum rod ensures no vibration after impact.
Changing counter weight is simple to change pendulum capacity, switching between 450J and 300J.
Customer can change striking knife according to test standard requirements, such as R2 for ISO/GB standard, R8 for ASTM, or R2/R8 instrumented knife, or Izod knife complying with ASTM E23.
Specimen holders have a few options, such as Charpy anvil, Izod vice, Brugger test fixture and wedge test fixture.
Pendulum lock & release system
It features damping design during pendulum locking to prevent any damages, lower noises and improve durability and safety.
Driving system:
This series adapts standard double speed reducer instead of old complicated driving system, featuring simple structure, easy repair, and high durability and free of maintenance.
Angle measurement system
Japanese made NEMICON high precision optical encoder is used for angle measurement, angle resolution can reach 0.025° to ensure high accuracy of impact energy.
Safety system:
This series of machine has fully closed protection shield to protect operator against specimen splitting during test, and to deny any access to the inside during test. Built-in door interlock further ensures operator safety. The protection shield is constructed with aluminum alloy profile for frame and fiber glass for easy observation. Split-type door design is simple to repair and change pendulum.
Energy display system
Three types of energy display are available:
Ø Dial gauge: simple and direct to read impact energy
Ø Wide view touch screen
Ø Computer with test software
Related Keywords
Related Keywords