
Solar System Use Popular Inverter Soncap Certificate Ep3000 Series 1kw to 6kw for Solar System Inverter 1kw
- Payment Type:
- L/C, T/T, D/P, Paypal, Money Gram, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen, China |
---|---|
Payment Type: | L/C, T/T, D/P, Paypal, Money Gram, Western Union |
Product Description
Product Description
Product Description
Solar system use popular inverter Soncap certificate EP3000 Series 1KW to 6KW for Solar System inverter 1kw
This home inversor(1KW-6KW), 12V/24V/48V inversor optional
With max 70A charge current, built in transfomrer and charger.
With pure sine wave output, and pure copper DC terminal port, to protect rust, more workable for critical environment.
This home inversor with durable construction for long life under extreme environmental conditions
Low idle current (less than 1 watt) conserves energy when no loads are present
Soft start capability for starting heavy loads, home invertsor
This inverter built-in starting control circuits for two- and three-wire generator starting systems
Simplified controls with a snap-on cover that protects settings from being accidentally changed
This home inverter with better thermal performance allows full output power to 50° C (122° F) without de-rating
This home inverter with high surge capacity starts more difficult loads and handles overload conditions reliably
Durable powder coated, corrosion resistant steel chassis
New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging, plus incorporates a robust ON/OFF switch and status indicators
Home inversor with 70-AMP automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance
New power factor corrected (PFC) charging, combined with a more sophisticated multi-stage battery charging algorithm, reduces electricity draw and generator run-time.
It's hot sale during all home inverter series, this home inverter with 12V/24V/48V model selectable, and very popular to overseas customers.
This home inversor(1KW-6KW), 12V/24V/48V inversor optional
With max 70A charge current, built in transfomrer and charger.
With pure sine wave output, and pure copper DC terminal port, to protect rust, more workable for critical environment.
This home inversor with durable construction for long life under extreme environmental conditions
Low idle current (less than 1 watt) conserves energy when no loads are present
Soft start capability for starting heavy loads, home invertsor
This inverter built-in starting control circuits for two- and three-wire generator starting systems
Simplified controls with a snap-on cover that protects settings from being accidentally changed
This home inverter with better thermal performance allows full output power to 50° C (122° F) without de-rating
This home inverter with high surge capacity starts more difficult loads and handles overload conditions reliably
Durable powder coated, corrosion resistant steel chassis
New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging, plus incorporates a robust ON/OFF switch and status indicators
Home inversor with 70-AMP automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance
New power factor corrected (PFC) charging, combined with a more sophisticated multi-stage battery charging algorithm, reduces electricity draw and generator run-time.
It's hot sale during all home inverter series, this home inverter with 12V/24V/48V model selectable, and very popular to overseas customers.
(EP3000) |
HV Model | |||||||
1012E | 1024E | 2012E | 2024E | 3024E | 4048E | 5048E | 6048E | |
Line Mode Specifications: | ||||||||
Input Voltage Waveform | Sinusoidal (utility or generator) | |||||||
Nominal Input Voltage | 230Vac(120VAC selectable) | |||||||
Low Line Disconnect | 184Vac±4% | |||||||
Low Line Re-connect | 194Vac ±4% | |||||||
High Line Disconnect | 265Vac±4% | |||||||
High Line Re-connect | 255Vac±4% | |||||||
Max AC Input Voltage | 270Vrms | |||||||
Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | |||||||
Low Line Frequency Re-connect | 58+0.3Hz for 60Hz;48+0.3Hz for 50Hz; | |||||||
Low Line Frequency Disconnect | 57+0.3Hz for 60Hz;47+0.3Hz for 50Hz; | |||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz;54+0.3Hz for 50Hz; | |||||||
High Line Frequency Disconnect |
65+0.3Hz for 60Hz;55+0.3Hz for 50Hz; |
|||||||
Output Voltage Waveform | As same as Input Waveform | |||||||
Over-Load Protection(SMPSload) | Circuit breaker | |||||||
Output Short Circuit Protection | Circuit breaker | |||||||
Efficiency (Line Mode) | >95% | |||||||
Transfer Switch Rating | 30A | |||||||
Transfer Time (Ac to Dc) | 10ms (typical) | |||||||
Transfer Time (Dc to Ac) | 10ms (typical) | |||||||
Pass through without Battery | Yes | |||||||
Max Bypass Overload Current | 30A | |||||||
Invert Mode Specifications: | ||||||||
Output Voltage Waveform | Sine wave | |||||||
Rated Output Power (VA) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||
Rated Output Power (W) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||
Power Factor | 0~1.0 | |||||||
Nominal Output Voltage (V) | 230Vac | |||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz | |||||||
Auto tracking Main Frequency(Hz) | Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz | |||||||
Output Voltage Regulation | ±10% rms | |||||||
Nominal Efficiency | >80% | |||||||
Over-Load Protection (SMPS load) |
(110% |
|||||||
Surge rating (10s) | 3000VA | 6000VA | 9000VA | 12000VA | 15000 VA | 18000VA | ||
Capable of starting electric motor | 1 HP | 1 HP | 2 HP | 3 HP | ||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||
Bypass Breaker Size | 30A | 30A | 30A | 35A | 50A | |||
Nominal DC Input Voltage | 12V | 24V | 12V | 24V | 24V | 48V | 48V | |
Min DC start voltage | 10V/20V/40V | |||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery | |||||||
Low DC input Shut-down | 10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery | |||||||
High DC input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery | |||||||
High DC input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery | |||||||
Power saver | Load ≤25W (Enabled on “P/S auto” setting of Remote control) | |||||||
Charge Mode Specifications: | ||||||||
Nominal Input Voltage | 230Vac | |||||||
Input Voltage Range | 196~243Vac | |||||||
Nominal Output Voltage | According to the battery type | |||||||
Nominal Charge Current | 35A | 35A | 65A | 35A | 45A | 35A | 40A | 50A |
Charge Current Regulation | ± 5Adc | |||||||
Battery initial voltage | 0 –15.7 Vdc (can operate with 0V battery) | |||||||
Charger Short Circuit Protection | Circuit breaker | |||||||
Over Charge Protection | Bat. V ≥15.7Vdc/31.4Vdc,beeps 0.5s every 1s & fault after 60s | |||||||
General Specifications | ||||||||
Safety Certification | CE | |||||||
Safety Certification | FCC | |||||||
Operating Temperature Range | 0°C to 40°C | |||||||
Storage temperature | 15°C below zero to 60°C | |||||||
Operation humidity | 5% to 95% | |||||||
Audible Noise | 60dB max | |||||||
Cooling | Forced air, variable speed fan | |||||||
Size |
1012E/1024E/2012E/2024E/2048E/3012E/3024E/3048E:580X315X300MM 4048E/5048E//6048E:755X319X288MM |
Related Keywords
Related Keywords
You May Also Like
You May Also Like