Must High Frequency 19 Inch Rack Mount Online UPS 1kVA-6kVA
  • Must High Frequency 19 Inch Rack Mount Online UPS 1kVA-6kVA
Must High Frequency 19 Inch Rack Mount Online UPS 1kVA-6kVA

Must High Frequency 19 Inch Rack Mount Online UPS 1kVA-6kVA

Payment Type:
L/C, T/T, D/P, Paypal, Western Union, O/A
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Payment Type: L/C, T/T, D/P, Paypal, Western Union, O/A
Product Description
Product Description

Product Description

Main features:

1. True on-line double conversion technology with advanced microprocessor control
2. Wide input voltage range
3. LCD display
4. Zero transfer time
5. Protection against all type of power problems
6. Self test while start of the UPS
7. Site wiring fault warning
8. On-battery power-on function
9. Smart RS232 communication interface
10. Intelligent slot available
Sealed lead-acid, maintenance free battery
Must High Frequency 19 Inch Rack Mount Online UPS 1kVA-6kVA

Product Series

Rack Mount 1~6kVA

Model

RT-C1K

RT-C2KS

RT-C3KS

RT-C6KS

Rated Power

VA/W

1kVA / 0.7kW

2kVA / 1.4kW

3kVA / 2.1kW

6kVA/4.2kW

Input

Nominal Voltage

220VAC

Voltage Range

115 ~ 300VAC

176 ~ 276VAC

Frequency Range

46 ~ 54Hz(default), user adjustable within 40~60Hz

46 ~ 54Hz

Power Factor

0.97

0.98

Connection

IEC320-10A inlet

IEC320-16A inlet

Terminal Block

Output

Voltage

220VAC ± 2%

220VAC ± 1%

Frequency

46~54Hz or 50Hz ± 0.2Hz (Line mode)
50Hz ± 0.2Hz ( Battery mode)

46~54Hz (Line mode)
50Hz ± 0.05Hz ( Battery mode)

Waveform

Sine Wave

Overload Capability

108%~150% for 30 sec., ³ 150% for 300 ms

105%~130% for 10 min., ³ 130% for 1 min.

Current Crest Ratio

3: 1

Bypass

Automatic Transfer

on overload and UPS failure

Before UPS Power-on

Default " NO" , user adjustable to " YES"

Yes

Voltage Range  

80~264VAC (Default), user adjustable within 80~286VAC

176 ~ 261VAC

Output Connections

IEC320 -10A * 4

IEC320-10A * 4

IEC320-10A and
Terminal Block

IEC320-10A * 4  and Terminal Block

Transfer Time

0 ms; less than 4 ms from inverter to bypass and vice versa

Zero

LED indicators

Status

Load level / Battery level, Battery, Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm

Bypass, On battery mode, Battery low, Overload, Fault

Communications

RS-232 Serial Interface

Intelligent Slot;
OPTIONS:   WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC)

Network Surge Protection

RJ45 I/O port available for network or Fax/Modem

Environmental

Operating Temperature

0 ~ 40° C

Operating Humidity

20 ~ 90% non-condensing

Main Unit

Net Weight (Kg)

15.3

10.3

11.2

18.3

Dimensions (W x D x H) mm

482.6 x 450 x 88 (2U)

482.6 x 600 x 130 (3U)

Battery Pack

Type

Internal Batteries

External Battery Pack

Nominal DC Voltage

36VDC

96VDC

240VDC

Backup Time (Full load)

5 min

9 min
(with 1 BP)

5 min
(with 1 BP)

7 min
(with 1 BP)

Net Weight (Kg)

--

25.3

58.2

Dimensions (W x D x H) mm

--

482.6 x 450 x 88 (2U)

482.6 x 600 x 130 (3U)