UPS for ATM Bank UPS Zero Transfer (EH5110)
- Payment Type:
- L/C, T/T, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | L/C, T/T, Western Union |
Product Description
Product Description
Product Description
1, wide input 160-300V
2, O transfer time
3, 1000va to 20kVA
4, LED or LCD display
5, tower or rack outlook
1. Smart RS232
2. ZERO transfer time
3. Intelligent slot available
4. Maintenance free battery
5. The best After-Sales Service
2, O transfer time
3, 1000va to 20kVA
4, LED or LCD display
5, tower or rack outlook
1. Smart RS232
2. ZERO transfer time
3. Intelligent slot available
4. Maintenance free battery
5. The best After-Sales Service
Model | EH1KR | EH1KRS | EH2KR | EH2KRS | EH3KR | EH3KRS | EH6KR | EH6KRS |
CAPACITY | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | 6000VA/4200W | ||||
INPUT | ||||||||
Phase | Single Phase with Ground | |||||||
Frequency Range | 50Hz:46~54Hz | |||||||
Power Factor | >=0.97 | >=0.98 | ||||||
Voltage Range | Base on load percentage (100%-80% / 80%-70% / 70%-60% / 60%-0%) | |||||||
Line Low Transfer | 160VAC/140VAC/120VAC/110VAC± 5VAC | 176 ±3% VAC | ||||||
Line Low Comeback | 175VAC ± 5VAC | 185 ± 3% VAC | ||||||
Line High Transfer | 300VAC± 5VAC | 276 ± 3% VAC | ||||||
Line High Comeback | 285VAC± 5VAC | 266 ± 3% VAC | ||||||
OUTPUT | ||||||||
Phase | Single | |||||||
Voltage | 220VAC/230VAC/240VAC | |||||||
Voltage Regulation | ± 2% | ± 1% | ||||||
Frequency( Synchronized Range) | 46~54Hz | |||||||
Frequency( Battery Mode) | 50 ± 0.2 Hz | 50Hz ± 0.05Hz | ||||||
Current Crest Ratio | 3:1 | |||||||
Harmonic Distortion | <= 4% THD ( Linear Load) / <= 7% THD ( Non-Linear Load) | <= 2% THD (Linear Load)/<= 6%THD(Non-Linear Load) | ||||||
Output Waveform | Pure Sinewave | |||||||
EFFICIENCY | ||||||||
To AC Mode | 85% | 85% | 85% | > 88% | ||||
To Battery Mode | 83% | 83% | 83% | > 88% | ||||
BATTERY | ||||||||
Battery Type | 12V/7Ah | Depending on the capacity of external batteries | 12V/7Ah | Depending on the capacity of external batteries | 12V/7Ah | Depending on the capacity of external batteries | 12V/7AH | Depending on the capacity of external batteries |
Numbers of Batteries | 3 | 8 | 8 | 20 | ||||
Backup Time(Full Load) | >5 minutes | >9 minutes | >5 minutes | 8 minutes | ||||
Recharge Time | 5 hours to 90% | 5 hours to 90% | 5 hours to 90% | 7 hours to 90% | ||||
Charging Current (Max.) | 1.0A | 7A | 1.0A | 8A+/-1A | 1.0A | 8A+/-1A | 2.0A | 4.2A |
Charging Voltage | 41.1Vdc ± 0.6V | 110Vdc ± 0.4V | 274Vdc ± 1%V | |||||
External Battery type | N/A | 12V/7.2AH *6 | N/A | 12V/7.2AH *8 | N/A | 12V/7.2AH *8 | N/A | 12V/7.2AH *20 |
TRANSFER TIME | ||||||||
AC to DC | Zero | |||||||
Inverter to Bypass | 2.5ms (Typical ) | Zero | ||||||
INDICATOR | ||||||||
Status | Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault | |||||||
AUDIBLE ALARM | ||||||||
Battery Mode | Sounding every 4 seconds | |||||||
Low Battery | Sounding every second | |||||||
Overload | Sounding twice every second | |||||||
Fault | Continuously Sounding | |||||||
DIMENSION | ||||||||
UPS CaseD x W H(mm) | 450x482.6x88 | 450x482.6x88 | 600x482.6x130 | |||||
Battery Case D x W x H | N/A | 450*482.6*88 | 450*482.6*88 | 600*482.6*130 | ||||
WEIGHT | ||||||||
UPS Case (kgs) | 14(w / battery) | 7 | 34.5(w / Battery) | 15 | 35.5(W / Battery) | 16 | 84(W / Battery) | 35 |
Battery Rack (kgs) | N/A | 22.5 | 27.8 | 27.8 | 64.2 | |||
ENVIRONMENT | ||||||||
Operating Environment | 0~40 Degrees Centigrade, 20~90% relative humidity (non-condensing) | |||||||
Noise Level | <45dB @ 1 Meter | 50dB @ 1 Meter | <55dB @ 1 meter | |||||
INTERFACE | ||||||||
Smart RS-232 | Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC | |||||||
SNMP (option) | Power management from SNMP manager and web browser |