100AMPS Voltage Solar Charge Controller for off-Grid Solar System
  • 100AMPS Voltage Solar Charge Controller for off-Grid Solar System
100AMPS Voltage Solar Charge Controller for off-Grid Solar System

100AMPS Voltage Solar Charge Controller for off-Grid Solar System

Payment Type:
L/C, T/T, Paypal
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen, Guangdong, China
Payment Type: L/C, T/T, Paypal
Product Description
Product Description
Instructions:
Charging and overvoltage instructions: When the system connection normal, and the sunshine exposure to light battery panels, charging indicator (1) is green normally on, means the system charging circuit is normal; When charging

Indicator (1) appear green and fast scintillation, means system overvoltage, dealing with the fault processing content. Charging process using the PWM mode, if in case of overdischarge, firstly charging should be reached to the hoist charging voltage, and keep 30 minutes, and then reduce to direct chargingvoltage, Keep 30 minutes, to activate the battery, avoid vulcanization crystallization, and finally reduce to float chargingvoltage and keep float chargingvoltage. If there is no over discharge happened, there will be no hoist charging way, in case of battery water loss.

1: Battery status indicator:

Battery voltage in the normal range, state lamp (2) is green normally on; When in the full state the indicator is green and slow flash; When the battery voltage reduced to undervoltage, state light turn into orange; When the battery voltage continue to reduce to the over discharge voltage, state lamp (2) turn into red, the controller will automatically shut down output, warn the user to supply electric power in time. When the battery voltage returned to normal working scope, will be automatically enabled output open, state lamp (2)turn into green.

2, Load instructions:

When the load is opening, the load lamp (3) is on normally, If the load current is more than the rated current of 1.25 times of the controller 60 seconds, or load is more than the rated current of 1.5 times of the controller 5 seconds, indicator lamp (3) for red slow flash, means overload, the controller will be closed output. When the load or side of the load appear short circuit fault, the controller will immediately closed output, indicator lamp (3) flash. Appear above-mentioned phenomenon, users shall carefully check the load connection condition. Disconnect the faulty load, press a key, after 10 seconds, then resume normal work, or wait until the next day it can work normally. In the work mode for general controller state, press akey to clear overload or short circuit indication, press the key again to make recovery output.