15kw LCD/LED Solar Panel Power Inverter with Built-in Solar Controller
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen Guangdong China |
---|---|
Payment Type: | T/T |
Product Description
Product Description
15KW LCD/LED Power Inverter with Built-in Solar Controller
Product Information:
This kind of solar / wind power off-grid inverter is pure sine wave intelligent inverter. Through the inverter power supply, DC 12v /24v /48v battery can be converted into AC 110v /220v, which used to the electronic products, such as water pump, air-condition, refrigerator etc. The solar power system consists of solar panel, solar controller, inverter, battery and other components.
According to used method can be divided into three types:
1. Only the converter;
2. Give priority to the use of solar energy;
3. Give priority to the use of AC.
You can customize the DC 36v inverter; Also can choose converting the AC 100v /AC 120v /AC 240v, which frequency is 50HZ /60HZ.
Product Picture:
Product Advantage:
1. CPU intelligent management;
2. Latest American technical inverter;
3. Adopted best electronic components, stable quality, long-life;
4. The high conversion efficiency reach to 90%-99%;
5. Low power consumption, when power is in 1W-6W, under sleep state.
Product Feature:
1. DC batteries is converted into AC pure sine wave output;
2. Built-in transfer switch automatically transfers between inverter power and incoming AC power.
3. CPU management, Intelligent control, module design;
4. LED / LCD display function;
5. The inverters' high conversion efficiency can reach to 90%-99%, and it has lower power consumption.
6. It can match with all kinds of batteries, such as sealed lead acid battery, open lead acid battery, gel battery and kinds of lithium batteries.
Attention please: If you want inverters to match the lithium batteries, you should tell me the lithium batteries specifications.
7. Three-step intelligent charging mode available. It charges all kinds of batteries intelligently, so can be used as a charger. And the maximum charging current is adjustable.
8. It is also called dynamic inverter that has the advantage of strong overload capacity. For example, 1KW model can drive 1P air conditioning, and 2KW can drive 2P air conditioning etc.
9. This kind of inverter adopts latest American low frequency circuit design and new electric materials. The whole system is more stable, low malfunction rate, and long-life. There is no problem to use for more than 5 years under the normally using.
10.1-year warranty plus life-time service.
11. Protection function:
(1) High voltage protection
(2) Under-voltage protection
(3) Over-temperature shutdown
(4) Automatic overload protection
(5) Short-circuit protection
Term of Payment:
T/T
Welcome to contact me at any time.
Product Information:
This kind of solar / wind power off-grid inverter is pure sine wave intelligent inverter. Through the inverter power supply, DC 12v /24v /48v battery can be converted into AC 110v /220v, which used to the electronic products, such as water pump, air-condition, refrigerator etc. The solar power system consists of solar panel, solar controller, inverter, battery and other components.
According to used method can be divided into three types:
1. Only the converter;
2. Give priority to the use of solar energy;
3. Give priority to the use of AC.
You can customize the DC 36v inverter; Also can choose converting the AC 100v /AC 120v /AC 240v, which frequency is 50HZ /60HZ.
Product Picture:
Product Advantage:
1. CPU intelligent management;
2. Latest American technical inverter;
3. Adopted best electronic components, stable quality, long-life;
4. The high conversion efficiency reach to 90%-99%;
5. Low power consumption, when power is in 1W-6W, under sleep state.
Product Feature:
1. DC batteries is converted into AC pure sine wave output;
2. Built-in transfer switch automatically transfers between inverter power and incoming AC power.
3. CPU management, Intelligent control, module design;
4. LED / LCD display function;
5. The inverters' high conversion efficiency can reach to 90%-99%, and it has lower power consumption.
6. It can match with all kinds of batteries, such as sealed lead acid battery, open lead acid battery, gel battery and kinds of lithium batteries.
Attention please: If you want inverters to match the lithium batteries, you should tell me the lithium batteries specifications.
7. Three-step intelligent charging mode available. It charges all kinds of batteries intelligently, so can be used as a charger. And the maximum charging current is adjustable.
8. It is also called dynamic inverter that has the advantage of strong overload capacity. For example, 1KW model can drive 1P air conditioning, and 2KW can drive 2P air conditioning etc.
9. This kind of inverter adopts latest American low frequency circuit design and new electric materials. The whole system is more stable, low malfunction rate, and long-life. There is no problem to use for more than 5 years under the normally using.
10.1-year warranty plus life-time service.
11. Protection function:
(1) High voltage protection
(2) Under-voltage protection
(3) Over-temperature shutdown
(4) Automatic overload protection
(5) Short-circuit protection
Term of Payment:
T/T
Welcome to contact me at any time.
Solar inverter parameters specifications | |||||||||||||||||||||||||||||||
Power Specifications | 7KW~15KW | ||||||||||||||||||||||||||||||
DC Input Specifications | |||||||||||||||||||||||||||||||
Rated Voltage Specifications | DC12/24/48/72V-AC220V | DC12/24/48/72V-AC110V | |||||||||||||||||||||||||||||
OperationVoltage Range (Normal Operating Battery Voltage) |
10V-16V (DC12V Power Supply) 20V-32V (DC24V Power Supply) 40V-64V (DC48V Power Supply) 60V-96V (DC72V Power Supply) |
||||||||||||||||||||||||||||||
Low Voltage Alarm(alarm to alert users when battery's voltage is over low) | 10.5Vdc ± 0.3Vdc (12V Power Supply) 21.0Vdc ± 0.6Vdc (24V Power Supply) 42.0Vdc ± 1.2Vdc (48V Power Supply) 63.0vdc ± 1.8Vdc (72V Power Supply) |
||||||||||||||||||||||||||||||
Low Voltage Shut off (shut off when battery's voltage is over low) | 10.0Vdc ± 0.3Vdc (12V Power Supply) 20.0Vdc ± 0.6Vdc (24V Power Supply) 40.0Vdc ± 1.2Vdc (48V Power Supply) 60.0Vdc ± 1.8Vdc (72V Power Supply) |
||||||||||||||||||||||||||||||
Low Voltage Recovery (Automatic Boot when Battery's voltage returns to Normal) |
12.0Vdc ± 0.3Vdc (12V Power Supply) 24.0Vdc ± 0.3Vdc (24V Power Supply) 48.0Vdc ± 0.3Vdc (48V Power Supply) 72.0Vdc ± 0.3Vdc (72V Power Supply) |
||||||||||||||||||||||||||||||
High Voltage Alarm and shut off ( alarms and shut off when the battery's voltage is over high) | 16Vdc ± 0.3Vdc (12V Power Supply) 32Vdc ± 0.6Vdc (24V Power Supply) 64Vdc ± 1.2Vdc (48V Power Supply) 96Vdc ± 1.8Vdc (72V Power Supply) |
||||||||||||||||||||||||||||||
High Voltage Recovery (Automatic boot when battery's voltage returns to normal) | 15.5Vdc ± 0.3Vdc (12V Power Supply) 31.0Vdc ± 0.6Vdc (24V Power Supply) 62.0Vdc ± 1.2Vdc (48V Power Supply) 93.0Vdc ± 1.8Vdc (72V Power Supply) |
||||||||||||||||||||||||||||||
Inverter Efficiency | ≥90% | ||||||||||||||||||||||||||||||
DC-priority type, battery low voltage conversion point when there is utility electricity bypass ( battery voltage is lower than this, turn to utility electricity to supply) | 11Vdc ± 0.3Vdc (12V Power Supply) 22Vdc ± 0.6Vdc (24V Power Supply) 44Vdc ± 1.2Vdc (48V Power Supply) 66Vdc ± 1.8Vdc (72V Power Supply) |
||||||||||||||||||||||||||||||
DC-priority type, after turning to utility electricity to supply, the battery low voltage recovery point (when the battery's voltage is higher than this, turn to battery to supply electricity) | 13.5Vdc ± 0.3Vdc (12V Power Supply) 27.0Vdc ± 0.6Vdc (24V Power Supply) 54.0Vdc ± 1.2Vdc (48V Power Supply) 81.0Vdc ± 1.8Vdc (72V Power Supply) |
||||||||||||||||||||||||||||||
AC Input Specifications | |||||||||||||||||||||||||||||||
Rated Voltage Specifications | 220VAC System | 110VAC System | |||||||||||||||||||||||||||||
Input Voltage Waveform | Sine wave (utility electricity or generator) | Sine wave (utility electricity or generator) | |||||||||||||||||||||||||||||
Rated Input Voltage | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac | |||||||||||||||||||||||||||||
Low Voltage Shut off | 180Vac±4% | 85Vac±4% | |||||||||||||||||||||||||||||
Low Voltage Recovery | 195Vac ±4% | 90Vac ±4% | |||||||||||||||||||||||||||||
High Voltage Shut off | 260Vac±4% | 135Vac±4% | |||||||||||||||||||||||||||||
High Voltage Recovery | 255Vac±4% | 130Vac±4% | |||||||||||||||||||||||||||||
Utility Electricity Charging rule | Three Stages: | ||||||||||||||||||||||||||||||
Constant current charging (constant stage)→constant voltage(constant voltage stage)→float (constant voltage stage) | |||||||||||||||||||||||||||||||
Utility Electricity Supply Efficiency | ≥98% | ||||||||||||||||||||||||||||||
Conversion Time (AC to DC) | <4ms | ||||||||||||||||||||||||||||||
Conversion Time (DC to AC) | <8ms | ||||||||||||||||||||||||||||||
AC output specifications | |||||||||||||||||||||||||||||||
Rated output voltage (V) | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac | |||||||||||||||||||||||||||||
OutputVoltage Range | ±10% rms | ||||||||||||||||||||||||||||||
Rated output frequency(Hz) | 50Hz ± 0.3Hz/60Hz ± 0.3Hz(Optional) | ||||||||||||||||||||||||||||||
Power Factor | 1.0 | ||||||||||||||||||||||||||||||
Output Waveform | Pure sine wave | ||||||||||||||||||||||||||||||
Waveform distortion rate( THD ) | ≤3% ( Linear load ) | ||||||||||||||||||||||||||||||
Dynamic Response( 0~100% ) | 5% | ||||||||||||||||||||||||||||||
Peak Factor ( CF ) | 3:1 | ||||||||||||||||||||||||||||||
Overload Protection (SMPS load) |
(110%<Load<125%) ±10% :after 15 minutes disconnecting the output voltage (125%<Load<150%) ±10% :after 1 minute disconnecting the output voltage (Load>150%) ±10% :after 20 seconds disconnecting the output voltage |
||||||||||||||||||||||||||||||
Other notes | |||||||||||||||||||||||||||||||
Continuous operation time | Continuous operation | ||||||||||||||||||||||||||||||
Normal Boot no-load Depletion | ≤Rated Power×2.5% | ||||||||||||||||||||||||||||||
No-load Depletion of energy-saving mode | ≤6W | ||||||||||||||||||||||||||||||
Safety Certification | CE(EN62040-1) EMC :EN62040-2, C2 | ||||||||||||||||||||||||||||||
Communication Interface | RS232 / (Customizable) | ||||||||||||||||||||||||||||||
Cooling | Temperature-controlled variable speed fan cooling (Ventilation condition) | ||||||||||||||||||||||||||||||
Noise( dB\1 meter ) | <60dB | ||||||||||||||||||||||||||||||
Ambient temperature ( ºC) | -10~+45 | ||||||||||||||||||||||||||||||
Storage Temperature( ºC) | -20~+55 | ||||||||||||||||||||||||||||||
Using Environment Humidity | 0-95% relative humidity(No condensation) | ||||||||||||||||||||||||||||||
Altitude( m ) | ≤5000( More than 1000 m, derating ) | ||||||||||||||||||||||||||||||
Display Way | LED Indicator +LCD Display | ||||||||||||||||||||||||||||||
Alarm Way | Buzzer sounds alarm | ||||||||||||||||||||||||||||||
Protection Functions | Low voltage protection, high voltage protection, high temperature protection, short circuit protection, leakage protection, overcurrent protection, overload protection, low recovery, high recovery, intelligent temperature control, solid barrier alarm | ||||||||||||||||||||||||||||||
Protection Level | IP20 / Customizable | ||||||||||||||||||||||||||||||
Solar Charge Controller Parameter Specifications | |||||||||||||||||||||||||||||||
Specifications | 12V/10A | 12V/20A | 12V/30A | 12V/40A | 12V/50A | 12V/80A | 12V/100A | ||||||||||||||||||||||||
Rated Power (W) | 120 | 240 | 360 | 480 | 600 | 960 | 1200 | ||||||||||||||||||||||||
Rated Charging Current(A) | 10 | 20 | 30 | 40 | 50 | 80 | 100 | ||||||||||||||||||||||||
Rated DC Voltage (V) | 12 | ||||||||||||||||||||||||||||||
PV Highest Voltage(V) | <25 | ||||||||||||||||||||||||||||||
PV Maximum Power (W) | 120 | 240 | 360 | 480 | 600 | 480×2 ways | 600×2 ways | ||||||||||||||||||||||||
Battery Overcharge Protection Voltage(V) | 14.3 | ||||||||||||||||||||||||||||||
Battery Overcharge Recovery Voltage(V) | 13.7 | ||||||||||||||||||||||||||||||
Battery Constant Voltage charging Voltage(V) | 13.5 | ||||||||||||||||||||||||||||||
Battery Over-discharging alarm Voltage(V) | 10 | ||||||||||||||||||||||||||||||
Protection Function | Night: anti-reverse charging, solar reversed | ||||||||||||||||||||||||||||||
Control Mode | PWM or MPPT | ||||||||||||||||||||||||||||||
Other Notes | Please refer to other solar controller manual | ||||||||||||||||||||||||||||||
Specifications | 24V/10A | 24V/20A | 24V/30A | 24V/40A | 24V/50A | 24V/60A | 24V/100A | ||||||||||||||||||||||||
Rated Power(W) | 240 | 480 | 720 | 960 | 1200 | 1440 | 2400 | ||||||||||||||||||||||||
Rated Charging Current(A) | 10 | 20 | 30 | 40 | 50 | 60 | 100 | ||||||||||||||||||||||||
Rated DC Voltage(V) | 24 | ||||||||||||||||||||||||||||||
PV Highest Voltage(V) | <50 | ||||||||||||||||||||||||||||||
PV Maximum Power (W) | 240 | 480 | 720 | 960 | 1200 | 1440 | 1200×2 ways | ||||||||||||||||||||||||
Battery Overcharge Protection Voltage(V) | 28.6 | ||||||||||||||||||||||||||||||
Battery Overcharge Recovery Voltage(V) | 27.4 | ||||||||||||||||||||||||||||||
Battery Constant Voltage charging Voltage(V) | 27.0 | ||||||||||||||||||||||||||||||
Battery Over-discharging alarm Voltage(V) | 20 | ||||||||||||||||||||||||||||||
Protection Function | Night: anti-reverse charging, solar reversed | ||||||||||||||||||||||||||||||
Control Mode | PWM or MPPT | ||||||||||||||||||||||||||||||
Other Notes | Please refer to other solar controller manual | ||||||||||||||||||||||||||||||
Specifications | 48V/20A | 48V/30A | 48V/40A | 48V/50A | 48V/60A | 48V/80A | 48V/100A | ||||||||||||||||||||||||
Rated Power(W) | 960 | 1440 | 1920 | 2400 | 2880 | 3840 | 4800 | ||||||||||||||||||||||||
Rated Charging Current(A) | 20 | 30 | 40 | 50 | 60 | 80 | 100 | ||||||||||||||||||||||||
Rated DC Voltage(V) | 48 | ||||||||||||||||||||||||||||||
PV Highest Voltage(V) | <100 | ||||||||||||||||||||||||||||||
PV Maximum Power (W) | 960 | 1440 | 1920 | 2400 | 1440×2 ways | 1920×2 ways | 2400×2 ways | ||||||||||||||||||||||||
Battery Overcharge Protection Voltage(V) | 28.657.2 | ||||||||||||||||||||||||||||||
Battery Overcharge Recovery Voltage(V) | 54.8 | ||||||||||||||||||||||||||||||
Battery Constant Voltage charging Voltage(V) | 54.0 | ||||||||||||||||||||||||||||||
Battery Over-discharging alarm Voltage(V) | 40 | ||||||||||||||||||||||||||||||
Protection Function | Night: anti-reverse charging, solar reversed | ||||||||||||||||||||||||||||||
Control Mode | PWM or MPPT | ||||||||||||||||||||||||||||||
Other Notes | Please refer to other solar controller manual | ||||||||||||||||||||||||||||||
Specifications and Model of Solar inverter with built-in Solar charge controller
|
Related Keywords
Related Keywords