Red LED Finger Pulse Oximeter For Kids , Fingertip Oxygen Saturation Monitor

Product Configuaration:

Function Configuration
Display Red LED
Spo2 parameter measurement Y
Pulse rate parameter measurement Y
Bar graph display Y
Automatic power-off function Y
Low-power UI icon indication Y
Abnormal parameter value alarm function with the measurement value sparkling Sel
Abnormal parameter value alarm function with the sound Sel
Pulse beat sound Sel
Pulse sound On/Off function Y

Attention : "Y" expresses the function item is the standard configuration , and the "Sel" expresses the function item will be configured according to the users’ demand .

1.2 Users : Pediatric , adult.

1.3 Major applications and scope

  • Is used in measuring the pulse oxygen saturation and pulse rate through finger ;
  • Is fit for family, hospital, oxygen bar, community healthcare, physical care in sports(It can be used
  • before or after doing sports and it is not recommended to use the device during the process of having sport) and etc ;
  • Not recommended to be used for monitoring the patients for a long time without any rest ;
  • Do NOT use the device in an MR/CT environment, in an exprosive atmosphere, or on infant or neonatal patient .
  • High temperature or high pressure steam disinfection for the oximeter is not permitted;Do not have the oximeter immerged in liquid ;
  • Operation of this device below the minimum amplitude of 0.4% modulation may cause inaccurate results
  • The device is designed to measure the percentage of arterial oxygen saturation of functional hemoglobin Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following :

Do not apply the pulse oximiter on the same arm as a blood pressure cuff, arterial catheter or infusion line(s)(IVs) .

Excessive light, such as sunlight or direct home lighting . Moisture in the device

Finger is outside recommended size range

Poor pulse quality

Venous pulsations

Anemia or low hemoglobin concentrations

Cardiogreen and other intravascular dyes

Carboxyhemoglobin

Methemoglobin

Dysfunctional hemoglobin

Artificial nails or fingernail polish .

Appearance

The above picture shows the appearance of EC-P60B , which is composed of main device, light emitter and the light sensor . The main device has such main components : button, OLED screen, battery component , and mechanical device which is divided into two parts .

Screen User Interface

The screen user interface has such information :

Spo2 parameter value and indication icon, 2-digit digital display ;

Pulse rate and indication icon , 3-digit digital display ;

Bar graph .

Pulse waveform .

Pulse beat icon .

Battery voltage indication icon .

Technical Specification

3.1 Power

Work voltage : DC 3V( 2 AAA Battery)

Work current : < 30mA

3.2 Screen Disply

Display screen : 0.96" Dual-color OLED display(blue and yellow)

Screen Resolution : 128*64

Display Mode : four directions display modes can switch through shortly pressing the button under 2 seconds .

3.3 Spo2 Parameter performance

Range : 35~100%

resolution : 1%

Accuracy(>=70%):

Without disturb or low perfusion : +-2%

Motion/Light disturb or low perfusion : +-3%

Accuracy(<70%): below 70% unspecified .

3.4 PR Parameter performance

Range : 25~254bpm

resolution : 1 bpm

Accuracy :

Without disturb or low perfusion : +-2bpm or +-2% , select the larger

Motion/Light disturb or low perfusion : +-3bpm or +-3% , select the larger

3.5 Blood Perfusion Index performance

Range : 0.2~20%

resolution: 0.1%

3.6 Low Perfusion performance Pi >= 0.4% : Spo2 and PR can be detected correctly ; Pi < 0.4% : Unspecified.

3.7 Pulse information The pulse waveform, pulse bar graph , pulse beating icon are showed on the screen .

3.8 Pulse sound The pulse beating sound is synchronous with the pulse beating icon sparkling and pulse waveform . Meanwhile the pulse beep can be manually closed through setting the pulse sound function or long pressing the button over 2 seconds.

3.9 Default Alarm Setting Spo2 alarm threshold : 90% ; PR alarm high threshold : 120bpm ; PR alarm low threshold : 50bpm ;

3.10 Alarm Sound When the parameter measurement value(PR , SPO2) is out of the alarm range , the alarm sound will inform the users , meanwhile the alarm sound can be manually closed through setting the alarm function or long pressing the button over 2 seconds .

3.11 Alarm information When the parameter measurement value(PR ,SPO2) is out of the default normal range, the relative alarm information will appear on the screen . The alarm information appears two kinds of types :

The measurement result sparkling with 1HZ frequency ;

The relative alarm string will roll and show on the screen .

The alarm function also can be closed through configuration, but the default configuration for the alarm function is open.

3.12 Anti light disturb performance The Spo2 and PR measurement result satisfy the demand in the normal room light disturb condition which is compared with the dark room condition .

3.13 Anti motion disturb performance

The Spo2 and PR measurement result satisfy the demand in the normal patient motion condition which is compared with the non-motion condition .

3.14 Durability performance The device is tough enough to withstand a minimum of 20 drops, is rugged enough to be used in the most demanding situations and exceeds IP32 water ingress testing .

3.15 On and off function There is a turn on button which also is the screen display mode switch button and the function setting button . The device will automatic turn off after the figure is out of the device over 6~8 seconds .

3.16 Enviroment requirements

Item Storage Working
Temperature -40~60°C 5~40°C
Humidity 5%~95% , non-condensing 30~80% , non-condening
Atmospheric Pressure 50~106KPa 70~106KPa

Measurement Mode : Spot checks

3.18 Battery working hour Under the continues working circumstance , theoretical working time is 32 hours . Allowing two AAA batteries to provide up to 4000 spot checks before being replaced .

3.19 Physical Identity Dimension : 66(L) × 36(W) × 33(H) mm Weight : About 60g (with the batteries)