Trusted Electrostatic Eliminator Generator And Bar
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Product Description
Product Description
china electrostatic eliminator generator and bar
install in production line

features
safe, shockless and touchable
Fast, thorough and effective static eliminating performance which can be applied on high speed production line.
prevent electric shock and fire hazard during production.
safty: the lastest technology from china, Un-shock
CE recognition
length: eache bar4M max
configuration: Alumiunm crust airproof dampproof, dustproof and easy fixed
safe, shockless and touchable
Fast, thorough and effective static eliminating performance which can be applied on high speed production line.
prevent electric shock and fire hazard during production.
safty: the lastest technology from china, Un-shock
CE recognition
length: eache bar4M max
configuration: Alumiunm crust airproof dampproof, dustproof and easy fixed
specification |
CD-106B |
Imput Voltage |
220V±10% 50/60HZ |
Output Voltage |
7.5-10KV |
Outout Power |
50W |
Effective distance |
10-80 |
Time positive |
0.1S |
Time negative |
0.2-O.3S |
install in production line

what cause static:
the most common cause are friction,pressure and separation, examples range from the unwinding of plastic fims to the everyday occurences of shocks from cars and door knobs. other causes include induction,whereby an insulator materials can become charged if itis brought into an electrical field temperature changr can also generate a static charge: a godd example is the generation of static charges on injection moulding as they cool.
AC static elimination
a normal mains 110/220V,50/60HZ AC supply is increased by a special transformer to typically 7KV AC. This high voltage is carried by a sheild HV cable to the static eliminator,where it is connected to an array of emitter pins that are stressed by the elevated voltage in proximity to an eartyed surfacr. this creates a high energy"corona" or "ion cloud".in which a very large number of positive and negative ions are generated. as the AC cycle changes,either positiveor negative ions are produced in approximately equal quantities, A staticallycharged of either polarity passing close to this ion cloud wil be quickly neutralized
the most common cause are friction,pressure and separation, examples range from the unwinding of plastic fims to the everyday occurences of shocks from cars and door knobs. other causes include induction,whereby an insulator materials can become charged if itis brought into an electrical field temperature changr can also generate a static charge: a godd example is the generation of static charges on injection moulding as they cool.
AC static elimination
a normal mains 110/220V,50/60HZ AC supply is increased by a special transformer to typically 7KV AC. This high voltage is carried by a sheild HV cable to the static eliminator,where it is connected to an array of emitter pins that are stressed by the elevated voltage in proximity to an eartyed surfacr. this creates a high energy"corona" or "ion cloud".in which a very large number of positive and negative ions are generated. as the AC cycle changes,either positiveor negative ions are produced in approximately equal quantities, A staticallycharged of either polarity passing close to this ion cloud wil be quickly neutralized
Related Keywords