1. Introduction:
New Air intelligent controller (KF-800M) can monitor real-time indoor temperature, CO2 concentration. Controller output signal can directly control the startup and speed of ventilator. It can be widely used in residential, commercial and industrial applications, and can effectively improve air quality, create a healthy, comfortable, energy-efficient living and working environment.
2. Buttons` function:
1.
2. button: parameter increase
3. button: parameter reduce
4. button: setting working mode for controller,
press this button slightly, the controller will be switched circularly between [AUTO
- MANUAL - TIMER - POWER OFF".
3. Display explanation:
![]() |
Time
Indoor
temperature CO2 concentration
Heating switch mode
Operating mode
Ventilator status
4. Detailed explanation:
1. AUTO (auto mode): high speed: CO2 concentration exceeds the setting concentration value of 300ppm; middle speed: CO2 concentration exceeds the setting concentration value of 100ppm; low speed: CO2 concentration exceeds the setting concentration value; stop: CO2 concentration is below the set concentration value.
2. MANUAL: set
the ventilator as OFF(stop).LOW(low speed).MED(middle speed).HIG((high
speed))by buttons and
, and under this mode, the ventilator will
run according to the setting, won`t be affected by CO2 concentration.
3. TIMER (timing mode): run according to set time & speed, can set from Monday to Sunday, 4 periods every day, and 28 periods in total.
4. Automatic mode
concentration value setting when the ventilator starts: under the auto mode, press or
button
for one second, it will appear CO2 concentration setting value and flicker,
then press
and
buttons to change the number (from 350
600ppm). Controller will return to normal working condition and save setting
parameter automatically if you won`t press any buttons more than 10 seconds
during the setting process.
5. Timing
parameter setting: press button
for 2 seconds to enter parameter setting. First enter [local time adjust",
press
button
to switch week, hour and minute, the corresponding parameter will flicker,
change the number by
and
buttons; after finishing adjusting local time,
press
button
to enter the first period hour setting on Monday, press
button
to switch hour, minute, and ventilator speed, press
and
buttons to change the number. After finish the
setting, press
button
to enter the second period hour setting on Monday-. Repeat above steps to
finish all the 28 periods setting. Controller will return to normal working
condition and save setting parameter automatically if you won`t press any
buttons more than 10 seconds during the setting process.
6. Backlight: CO2 concentration less than 500ppm (green backlight), 500-799ppm (yellow backlight), higher than 800ppm (red backlight).
5. Specification:
* Dimension: 868640mm * Warm-up time: 1 minute
* Fixing hole distance:60mm(standard) * Response time: 10 seconds
* Wiring terminal: Max 2.5 mm2 wire * Recovery time: 30 seconds
* Rated voltage: AC220V 50Hz * Operating temperature: -10 --- +50
* Standby Power: 0.5W * Operating humidity: 5%RH--90%RH
* Control power: 200W * Storage temperature: -10 --- +60
* Output interface: Three-speed ventilator * Storage humidity: 60%RH
* Temperature display range:0--50 * Life: 10 years
* CO2 display range: 350ppm--3000ppm